The bollard comes pre-wired (electric motor, limit switches, LEDs and possible optional items such as: beeper, solenoid valve and
pressure switch). Connections are in a dedicated watertight box.
Remove the connector from the junction box and bring the connections to the respective terminals by means of a multicore
cable (not supplied with the equipment).
Retractable Oil-hydraulic Bollard
English
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
53
51
17
16
52
18
IP 66
IP 66
!
!
Pre-wiring box
with connector
led
flasher
and/or beeper
motor
common
led and/or beeper common
motor live
(Pic. 17)
[B]
motor live
(Pic. 17)
[B]
Card of the
“Heater
Talos series”
(if mounted)
ATTENTION: a 40 μF capacitor is pre-wired inside the junction box. For the Talos option 4 mm
thickness (fe steel and Inox/stainless steel) do NOT connect any more capacitors to the terminals
A and B of the Elpro S40 controller unless required to achieve a good performance of the bollard.
For the Talos option 12 mm thickness a 20 μF capacitor is required to be added to the terminals A
and B of Elpro S40.
Pic. 14
ATTENTION: TIGHTEN THE CABLE GLAND VERY
HARD BEFORE FITTING BACK THE CONNECTOR,
OTHERWISE GRADE OF PROTECTION FROM
SEEPAGE MAY BE AFFECTED.
1
2
pressure switch (if fitted)
to be series connected with
the other safety accessories
12
11
56
ground limit switch
blue and gray cables - green wires
limit switch opening
gray cable - white wire
(Pic. 16)
[C]
limit switch closing
blue cable - white wire (Pic. 16)
[C]
55
limit 24 Vdc
blue and gray cables - brown wires
(see the instructions enclosed with the item)
Connections to the terminals
in the Elpro S40 controller
16
15
16
15
24 Vdc
23
22
9
10
24 Vdc power supply
for presence sensor
power supply
230 V voltage stabilizer
50 Hz for solenoid valve
24 Vdc
In case of solenoid valve only
or solenoid valve with
obstacle detector
In case only the obstacle detector
is installed
11