Pic. 3
INSTALLATION DISTANCES FOR THE GATE TO OPEN INWARDS
Gate stop in
closed position
Gate stop in
open position
90°
5
Stroke C (mm)
A
B
D (max) E
L
280
140
130
70
80
620
280 braking
110
130
70
80
615
400
180
200
130
110
820
400 braking
170
180
120
110
810
500
240
240
170
140
965
500* braking
220
220
150
140
965
600* braking
150
380
*
140
1.220
700* braking
180
450
*
160
1.380
800* braking
200
520
*
180
1.550
900* braking
230
580
*
200
1.710
1.000* braking
240
670
*
220
1.890
* The installation dimensions for the special strokes have been studied to take full advantage of the braking action in
opening and closing cycles. In case any of the special strokes be required in non braking version, our technical team
should be contacted and complete details of the gates provided for evaluation.
Installation distances in (mm) for opening
90°
B
A
L
C
D
E
Misalignment of the
fixing plates: 18-20 mm
MAX. GATE WIDTH PER LEAF (m)
The gate structure, design (solid, in-filled),
height and strong wind pressure may affect
and decrease the indicated values. Make
always sure the gate structure is adequate to
automation.
100
1
2
3
4
2,8
200
300
400
500
600
700
corsa 280 mm
corsa 400 mm
Stroke 280 mm
Stroke 400 mm
M
A
X
. G
A
T
E
W
E
IG
H
T
P
E
R
L
E
A
F
(
k
g)
MEC 800 Special
External oil-hydraulic operator for swinging gates
of large dimensions. With separate motor-pump.