ELECTRICAL WIRING DIAGRAM AND LAYOUT OF THE ACCESSORIES
Before installing MEC 800 Special it is advisable that preparatory work be carried out for all of the accessories required at least to
ensure safety and proper control of the system.
1 - 230 V - 50 Hz - 0,03 A magnet
o-thermal circuit breaker (cable section recommended 2,5 mm² beyond 100 m)
2 - Elpro 27 control box with VIX 53/2 R plu-in radio receiver
3 - MEC 700/80 Ventil motor pump inside its protection housing
4 - Hoses
5 - 4-way pipe block
6 - Rigid copper pipes
7 - Miri 4 flasher with aerial
8 - MEC 800 special actuator
9 - Fit 55 photocell receiver
10 - Junction pit
11 - Gate stop in open position (*)
12 - Fit 55 photocell transmitter on post mount
13 - Fit 55 photocell receiver on post mount
14 - Gate electric lock
15 - Fit 55 photocell transmitter
16 - Gate stop in closed position (*)
17 - Chis 37 key-switch
18 - VIX 53 hand held radio transmitter
230 V - 50 Hz ±10%
4x1,5 mm²
Fig. 2
(*)
NOTE VERY WELL: the gate stops in open and closed positions are most
important for the correct and safe functioning of MEC 800 Special.
!
General layout: it is the installer’s care and responsibility to properly lay the pipes and tubes for the connections.
2
3
4
1
7
8
9
11
10
4
12
13
14
16
15
17
18
2x1 mm²
RG58
4x1 mm²
4x1 mm²
4x1 mm²
2x1 mm²
2x1 mm²
2x1 mm²
5
6
4x1,5 mm²
MEC 800 Special
External oil-hydraulic operator for swinging gates
of large dimensions. With separate motor-pump.
En