background image

  4

!

10-15 cm

Fibo 300 LB

Fibo 400 LB

FIXING THE GATE TO THE CHAIN

To properly  x the gate to the chain, consider a clearance of 10-15 cm between the  xing point and the center lines of the geared 
motor and chain stretcher respectively, once the gate has reached the ends of the permitted travel (Pic. 2).

Pic. 2

electro-mechanical geared motor

with chain-drive system for heavy industrial sliding gates

Chain stretcher: existing  chain stretchers  pre- tted 
on the gate can be used, depending on the type of 
chain  and  gate;  the  picture  here  represented  is 
merely indicative. 

Release lever

Pinion:

depending on the type

of pinion and chain, the

number of teeth and 

pitch can change 

OVERRIDE FOR MANUAL OPERATION 

In order to disconnect the gate from the FIBO 300 LB - FIBO 400 LB geared motors, in situations where power failure is occurring 
or during the installation phases, it is required that the override handle be operated. This  can be carried out even at a distance 
from the motor by means of a metal rope operated by a release lever (Pic. 3).

Pic. 4

Limit switch
striking plate

Drive chain

Limit switch 

block of terminals

in the Elpro

controller

 

NC contact

limit switches

INSTALLING THE LIMIT SWITCHES

The limit switches are to be installed in such a way that the striking plate (also  tted to the chain) can activate the switches 
without problems. The electrical connections must comply with the instructions of the Elpro electronic controller (Pic. 4).

Содержание FIBO 300 LB-1,5 HP

Страница 1: ...300 LB 1 5 HP FIBO 400 LB 3 0 HP Electro mechanical geared motor for heavy industrial sliding gates Worm crown gear inner coupling in an oil bath entirely supported by ball bearings Chain drive Three...

Страница 2: ...DECLARATION OF CONFORMITY of the manufacturer Meccanica Fadini snc Via Mantova 177 A 37053 Cerea VR Italy declares under own responsibility that Fibo 300 LB Fibo 400 LB comply with the 2006 42 CE Mac...

Страница 3: ...ors for heavy sliding gates driven bya chain it is available in 1 1 kW 1 5 HPthree phase and 2 2 kW 3 0 HP three phase versions FIBO 300 LB FIBO 400 LB are a versatile motor powered units and can suit...

Страница 4: ...nd chain the number of teeth and pitch can change OVERRIDE FOR MANUAL OPERATION In order to disconnect the gate from the FIBO 300 LB FIBO 400 LB geared motors in situations where power failure is occu...

Страница 5: ...ccessories here included Supply voltage 230 V 50 60 Hz NOTE WELL the entire electrical equipment is to be properly connected to ground 1 230 V 50 60 Hz 0 03 A magneto thermal di erential circuit break...

Страница 6: ...Fibo 400 LB MOTOR CONNECTIONS Pic 6 Motor terminal board Elpro 37 HP with power contactors 400 V Three phase connections electro mechanical geared motor with chain drive system for heavy industrial s...

Страница 7: ...60 Hz 11 m 1 Hydraulic oil type Oil Fadini art 706L Working temperature 25 C 80 C Fibo 300 LB weight 28 kg Protection standard IP 55 PERFORMANCE Service cycle 25 s opening 30 s dwell 25 s closing 30...

Страница 8: ...PERFORMANCE Service cycle 25 s opening 30 s dwell 25 s closing 30 s dwell Complete cycle time 110 s Complete opening dwell closing dwell cycles No 33 hour Annual cycles with 8 hours of use per day No...