![fadini FIBO 300 LB-1,5 HP Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/fadini/fibo-300-lb-1-5-hp/fibo-300-lb-1-5-hp_instruction-manual_3172376005.webp)
5
!
1
2
9
8
3
4
5
6
7
8
7
10
Fibo 300 LB
Fibo 400 LB
General layout for guidance: it is the installer’s responsibility to lay the conduits for the electrical connections in a proper and correct
way.
electro-mechanical geared motor
with chain-drive system for heavy industrial sliding gates
GENERAL LAYOUT OF THE INSTALLATION
For installations where large gates are involved, pre-existing accessories can be found, speci cally dedicated to the type of gate
to be operated. Therefore the installation diagram of the components as represented below is to be considered only indicative,
and cannot be limited to the accessories here included.
Supply voltage
230 V - 50/60 Hz
NOTE WELL: the entire electrical equipment is to be properly connected to ground.
1 - 230 V - 50/60 Hz, 0,03 A, magneto-thermal differential circuit breaker (not included)
2 - Control board with power contactors and plug-in radio receiver card
3 - Three-phase FIBO 300 LB or FIBO 400 LB geared motor
4 - Flasher
5 - Opening external limit switch
6 - Closing external limit switch
7 - Photocell transmitter
8 - Photocell receiver
9 - Key-switch
10 - Transmitter
Pic. 5
Types of cables to be used:
For power supply to motors, safety and command accessories: FROR CEI 20-20 CEI EN 50267-2-1
For the aerial: RG58 (included, 3 m)
NOTE: for distances beyond 50 m increase the cable square section to suit the real absorption requirements of the
devices as indicated in the CEI EN 60204-1 norms.