manualshive.com logo in svg
background image

the gate opener

Made in Italy

E

lpro12

PLUS

GB

Flashing lamp:

19 20

 230V MAX 25W

4

ON: Pre-flashing

OFF: No pre-flashing

Power supply:

OPERATING MODES

HIGH VOLTAGE ELECTRICAL CONNECTIONS

7

ON: Lamp is not operating during
       Dwell time. Automatic mode.

OFF: It flashes during Dwell Time.
        Automatic Mode.

POWER SUPPLY

230V 50Hz SINGLE-PHASE

21 22

DIP-SWITCH 4 and 7:

1

2

Button switch:

3

4

5

6

ST

OP

COMMON/

NEUTRAL

OPOEN

CL
OSE

Photocells and Safety Edge:

12 13

1

DIP-SWITCH 1:

ON: Photocells stop gate while opening,
       reverse it once obstacle is removed

OFF: Photocells do not stop gate while
        opening, reverse it in case of an
        obstacle

PHOTOCELLS
AND SAFETY EDGE

24V OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)

Limit switch:

LIMIT SWIT

CH

CL
OSE

NEUTRAL

10

8

9

LIMIT SWIT

CH

OPEN

Light ON = Open gate
Light OFF = Close gate
Flashing (fast) 0.5s= Closing gate
Flashing (normally) 1s= Opening gate
Flashing (slowly) 2s= gate is stopped

24V 3W Indication Light:

3

11

Push Button Switch Pulin 3:

26

27

28

3

NEUTRAL

Led to indicate status

of Open - Stop - Close

switches

Safety Contact:

This contact must be
N.C. for the control
panel to be allowed
to work

Radio Contact:

COMMON/

NEUTRAL

CONT

ACT

RADIO

7

3

- Open/Close (Standard)
- Travel reversing on
  pulsing
- Step by step

2

ON: Gate is not reversed while opening

OFF: Any pulse reverses the gate

5

ON: Step by step. Stop in between

OFF: Standard operating mode

DIP-SWITCH 2 and 5 (NEVER set BOTH of them
ON at the same time):

14 15

LOW VOLTAGE ELECTRICAL CONNECTIONS

Capacitor and Single-phase Motor:

-

+

R65

MOTOR RUN

TIME

OPEN/CLOSE

FROM 2 UP TO 128s

R64

-

+

DWELL TIME

FROM 2 UP TO 128s

29 30

18

16 17

NEUTRAL

M

Capacitor

20µF for 0.5HP
40µF for 1.0HP

Courtesy Light
230V max. 100W:

23 24

Trimmer R63

-

+

COURTESY LIGHT

FROM 2 UP TO 255s

How it works: Set the clock to the required times. On the pre-set time the gate is automatically opened and held open. Any
further pulsing (even by remote control) is not accepted by the system until the time pre-set by the clock has expired. On
expiring and after the pre-set dwell time the gate is closed automatically.
R62 trimmer on to zero, Dip-Switch 3=ON.

DIP-SWITCH No.3=ON Automatic Closing

Time clock:

3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic
          closing by pulse

4

3

COMMON

COMMON

OPEN

NO

-

+

Pedestrian Trimmer R62

set on to zero

Hold on switched (Deadman) control:

Pedestrian Opening:

Trimmer R62

-

+

from 3 to 30s. It can be activated

by any pulse (eg. by remote

control) superior to 2s

3

DIP-SWITCH 3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic
          closing by pulse

Automatic / Semiautomatic:

Automatic Operation: any pulse opens the gate, the gate
stays open as long as the Dwell time expires as set by R64
trimmer, then it closes automatically, no pulsing is required.

Semi-automatic Operation: any pulse opens the gate
that stays open. A second pulse to Close is required for
the gate to close.

Open and Close operations are achieved "by
holding a switch on" (no relay self-holding in
involved) therefore a phisical attendance is
required to keep the gate opening or closing
until either the button or key is released.

DIP-SWITCH 6

6

ON= Deadman Control. Dip-switch 4=OFF
         and Dip-switch 3=OFF

OFF= Standard Operations

Dwell Time

from 2 to 128s

-

+

Trimmer R64

COMMON

OPEN

4

3

Drwg. No. 4086