In case of failure of the panel:
- Check voltage supply. It must be 230V 50Hz single-phase
- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the control
  panel to the electric motor

Led Status Indication:

L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button

L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open

The electronic control panel Elpro 12 Plus, new generation, is designed to operate the sliding gate operator Nyota 115. Power supply is 230V 50Hz
single-phase. Built in full compliance with BT 93/68/CE Low Voltage and EMC 93/68/CE Electro-Magnetic Compatibility Regulations. Fitting operations
are recommended by a qualified technician in conformity to the existing safety standards.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the
control panel any time.

PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5mm² section wires for voltage supply, electric motor and flashing lamp.
  Maximum recommended distance 50m.
  Use 1mm² section wires for limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.

DIP-SWITCH

1

4 5 6 7 8

2

ON

OFF

3

Dip-Switch:

1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function

E

lpro12

PLUS

GB

L7= Gate Status; it flashes on gate opening

the gate opener

Made in Italy

PULIN 3

26

27

28

3

DIP-SWITCH

ON

OFF

1

4 5 6 7 8

2 3

L2

L3

L4

L5

L9

L8

L6

L7

L1

F4 Fuse = 1A

24V Transformer

Protection

RADIO

PLUG-IN

CARD

CONNECTOR

PEDESTRIAN OPENING

from 3 up to 30s

-

+

ELPRO 12 PLUS

18

16 17

NEUTRAL

M

SINGLE-PHASE
ELECTRIC
MOTOR

24V OUTPUT (max

. load:

2 P
AIRS PHO

TOCELLS

1 RADIO RECEIVER)

INDICA

TION LAMP

24V max

. 3W

ST

OP

NEUTRAL

PUSH BUTT

ONS

OPEN

CL
OSE

PHO

TOCELLS

SAFETY EDGES

RADIO CONT

ACT

LIMIT SWIT

CH CL

OSE

LIMIT SWIT

CH OPEN

LIMIT SWIT

CH NEUTRAL

-

+

-

+

-

+

R65

R64

R63

R62

COURTESY LIGHT

from 2 up to 255s

DWELL TIME

from 2 up to 128s

MO

TOR RUN TIME

OPEN/CL

OSE

from 2 up to 128s

F3 Fuse = 630mA

Transformer Protection

F2 Fuse = 8A

Mains

F1 Fuse = 8A

Mains

19 20 21 22

29

23 24

30

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15

SAFETY CONT

ACT

COURTESY LIGHT

100W max

.

CAP

ACIT

OR

230V 25W max

.

FLA

SHING LAMP

230V SINGLE

-PHA

SE

VOL

TAGE SUPPL

Y

TRANSFORMER

TRIMMER

Drwg. No. 4086

MICROPROCESSOR

E 12 plus 1 4