In case of failure of the panel:
- Check voltage supply. It must be 230V 50Hz single-phase
- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the control
panel to the electric motor
Led Status Indication:
L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button
L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open
The electronic control panel Elpro 12 Plus, new generation, is designed to operate the sliding gate operator Nyota 115. Power supply is 230V 50Hz
single-phase. Built in full compliance with BT 93/68/CE Low Voltage and EMC 93/68/CE Electro-Magnetic Compatibility Regulations. Fitting operations
are recommended by a qualified technician in conformity to the existing safety standards.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the
control panel any time.
PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5mm² section wires for voltage supply, electric motor and flashing lamp.
Maximum recommended distance 50m.
Use 1mm² section wires for limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
DIP-SWITCH
1
4 5 6 7 8
2
ON
OFF
3
Dip-Switch:
1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function
E
lpro12
PLUS
GB
L7= Gate Status; it flashes on gate opening
the gate opener
Made in Italy
PULIN 3
26
27
28
3
DIP-SWITCH
ON
OFF
1
4 5 6 7 8
2 3
L2
L3
L4
L5
L9
L8
L6
L7
L1
F4 Fuse = 1A
24V Transformer
Protection
RADIO
PLUG-IN
CARD
CONNECTOR
PEDESTRIAN OPENING
from 3 up to 30s
-
+
ELPRO 12 PLUS
18
16 17
NEUTRAL
M
SINGLE-PHASE
ELECTRIC
MOTOR
24V OUTPUT (max
. load:
2 P
AIRS PHO
TOCELLS
1 RADIO RECEIVER)
INDICA
TION LAMP
24V max
. 3W
ST
OP
NEUTRAL
PUSH BUTT
ONS
OPEN
CL
OSE
PHO
TOCELLS
SAFETY EDGES
RADIO CONT
ACT
LIMIT SWIT
CH CL
OSE
LIMIT SWIT
CH OPEN
LIMIT SWIT
CH NEUTRAL
-
+
-
+
-
+
R65
R64
R63
R62
COURTESY LIGHT
from 2 up to 255s
DWELL TIME
from 2 up to 128s
MO
TOR RUN TIME
OPEN/CL
OSE
from 2 up to 128s
F3 Fuse = 630mA
Transformer Protection
F2 Fuse = 8A
Mains
F1 Fuse = 8A
Mains
19 20 21 22
29
23 24
30
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
SAFETY CONT
ACT
COURTESY LIGHT
100W max
.
CAP
ACIT
OR
230V 25W max
.
FLA
SHING LAMP
230V SINGLE
-PHA
SE
VOL
TAGE SUPPL
Y
TRANSFORMER
TRIMMER
Drwg. No. 4086
MICROPROCESSOR
E 12 plus 1 4