ELECTRICAL WIRING DIAGRAM AND LAYOUT OF THE ACCESSORIES
Before installing Aproli 280 Batt it is advisable that preparatory work be carried out for all of the accessories required at least to
ensure safety and proper control of the system.
1 - 230 V - 50 Hz - 0,03 A magnet
o-thermal circuit breaker (cable section recommended 2,5 mm² beyond 100 m)
2 - Elpro 27 control box with VIX 53/2 R plug-in radio receiver
3 - Aproli 280 Batt
4 - Miri 4 flasher with aerial
5 - Fit 55 photocell receiver
6 - Junction pit
7 - Fit 55 photocell transmitter on post mount
8 - Ground gate stop in open position
9 - Fit 55 photocell receiver on post mount
10 - Gate electric lock
11 - Gate stop in closed position (*)
12 - Fit 55 photocell transmitter on post mount
13 - Chis 37 keyswitch
14 - Vix 53 radio transmitter
230 V - 50 Hz ±10%
4x1,5 mm²
Pic. 2
General layout: it is the installer’s care and responsibility to properly lay the tubes required for the electrical connections.
En
g
lis
h
2
3
4
1
7
8
9
11
10
4
12
13
14
4x1 mm²
4x1 mm²
4x1 mm²
4x1 mm²
2x1 mm²
2x1 mm²
2x1 mm²
5
6
2x1 mm²
RG58
(*)
IMPORTANT: ground gate stops in open and closed gate positions are
most important for proper operations and therefore safety of the system
equipped with Aproli 280 Batt.
!
External oil-hydraulic operator with articulated arm
for swinging gates mounted on large pillars
APROLI 280 Batt