CE RoHS
Technical Data
Supply voltage : Three phase 415V AC 50/60 Hz
All O/P's with Soft start
Max. Load capacity: 24 Kilo Watts
* (Load must be balanced across all 3 outputs max 8Kw each)
Over Temperature Protection: On each O/P - Led indicators 1,2 & 3
Mains I/P : Neutral (Blue)
terminal #1
Live 1 (Brown)
terminal #2
Live 2 (Black)
terminal #3
Live 3 (Grey)
terminal #4
Mains O/P : Switched Live 1 (Brown)
terminal #5
Soft start
Switched Live 2 (Black)
terminal #6
Switched Live 3 (Grey)
terminal #7
Neutral return out (Blue)
terminal #8-13
Earth out (Green/Yellow)
terminal #14
PIR I/P :
Live trigger input Zone 1
terminal #15
Auxiliary
Live trigger input Zone 2
terminal #16
Device
Live trigger input Zone 3
terminal #17
Ext. Sw. I/P : Ext. SW1 Zone 1
terminal #18 a+b
Auxiliary
Ext. SW2 Zone 2
terminal #19 a+b
Device
Ext. SW3 Zone 3
terminal #20 a+b
QHVC-S I/P : 0V
terminal #21
Auxiliary Zone 1
terminal #22
Device
Zone 2
terminal #23
Optional
Zone 3
terminal #24
5V
terminal #25
IP Rating:
IP53
Dimensions : 350mm x 330mm x 150mm Note : Terminal connections are the same
Weights :
QHC18M – 10 Kg
for both the QHC24M
QHC24M – 12 Kg & QHC24MR controllers.
Tel. 00 353 1 8352718 Email:
[email protected] [email protected]
Factron Ltd. Unit 12 Ashbourne Ind. Park, Ashbourne, Co.Meath , A84 HY74, Ireland
Содержание QHC24MR
Страница 7: ...Page 6...