  Technical Data       

Supply voltage : Three phase 415V AC  50/60 Hz

All O/P's with Soft start

Max. Load capacity: 24 Kilo Watts 

* (Load must be balanced across all 3 outputs max 8Kw each)

Over Temperature Protection: On each O/P  -  Led indicators 1,2 & 3

Mains I/P :      Neutral (Blue)

terminal #1

             Live 1 (Brown)

terminal #2

             Live 2 (Black)

terminal #3

             Live 3 (Grey)

terminal #4

Mains O/P :    Switched Live 1 (Brown)

terminal #5

Soft start

 Switched Live 2 (Black)

terminal #6

             Switched Live 3 (Grey)

terminal #7

                                     Neutral return out  (Blue)

terminal #8-13

              Earth out  (Green/Yellow)

terminal #14

PIR I/P :  

  Live trigger input  Zone 1

terminal #15

Auxiliary

  Live trigger input  Zone 2

terminal #16

Device 

  Live trigger input  Zone 3

terminal #17

Ext. Sw. I/P :   Ext. SW1  Zone 1

terminal #18 a+b

Auxiliary

  Ext. SW2  Zone 2

terminal #19 a+b

Device 

  Ext. SW3  Zone 3

terminal #20 a+b

QHVC-S I/P : 0V 

terminal #21    

Auxiliary         Zone 1

terminal #22          

Device

  Zone 2

terminal #23         

Optional

  Zone 3

terminal #24          

           5V 

terminal #25         

 IP Rating:

 IP53      

Dimensions :  350mm x 330mm x 150mm                    Note : Terminal connections are the same 
Weights :  

 QHC18M – 10 Kg

                               for both the QHC24M 

 QHC24M – 12 Kg                                              & QHC24MR controllers.   

          

 

           

 

                                                                                                                                     

Tel. 00 353 1 8352718   Email:  

[email protected]   [email protected]  

 

 

Website: 

www.factron.ie

Factron Ltd.   Unit 12 Ashbourne Ind. Park, Ashbourne, Co.Meath , A84 HY74, Ireland

Содержание QHC24MR

Страница 1: ...QHC24MR 24Kw Heater Controller 3 channel Receiver Remote Manual operation Quick start guide Three phase 415v Three zone Remote Manual Soft star...

Страница 2: ...Service hatch Isolation switch 40A O P MCBs 40A Type C Power control dial 5 settings Manual Remote Power ON indicator Over Temp indicators Front panel QHVCR remote Master Controller Antenna Power Pow...

Страница 3: ...he Neutral OUT to the blue terminals marked N Connect the Earth to the green yellow Earth terminals Then connect the heaters to the other side of the terminals to the appropriate connections Live conn...

Страница 4: ...Din Rail connections Distribution Box P No QHDB 1824 Terminals 1 O P1 Terminals 2 O P2 Terminals 3 O P3 Blue terminals N N out Green Yellow terminals Earth Important Only a qualified electrician shou...

Страница 5: ...units which are preset to Yellow Red zones are controlled by the Yellow Red control knobs respectively and will operate as above in 10 5 The QHVCR unit is powered by 3 x AAA battery s So the unit wil...

Страница 6: ...h the receiver marked 0 Setting the left rotary switch to 1 so the transmitter marked 1 will communicate with a receiver also marked 1 If the transmitter and receiver are not paired correctly they wil...

Страница 7: ...Page 6...

Страница 8: ...Yellow terminal 14 PIR I P Live trigger input Zone 1 terminal 15 Auxiliary Live trigger input Zone 2 terminal 16 Device Live trigger input Zone 3 terminal 17 Ext Sw I P Ext SW1 Zone 1 terminal 18 a b...

Отзывы: