![FactoryCat 390 Series Скачать руководство пользователя страница 24](http://html2.mh-extra.com/html/factorycat/390-series/390-series_operators-manual_3157516024.webp)
PAGE 19-1
YEARLY MAINTENANCE
1. CALL YOUR LOCAL DEALER FOR YEARLY MAINTENANCE
STORING MACHINE
1. BE SURE TO FLUSH THE TANKS OUT COMPLETELY, AND TO
DRAIN ALL WATER FROM THE MACHINE.
2. OPEN THE RECOVERY TANK LID TO PROMOTE AIR
CIRCULATION.
3. RAISE BRUSHES AND SQUEEGEE.
DAILY MAINTENANCE
1. REMOVE AND CLEAN PADS OR BRUSHES. NEVER
USE SOILED PADS WHEN CLEANING. REPLACE
PADS WHEN THEY BECOME PACKED WITH RESIDUE.
2. REMOVE AND CLEAN DEBRIS FROM THE FLOAT
SHUT-OFF SCREEN LOCATED INSIDE THE RECOVERY
TANK.
3. DRAIN AND RINSE TANKS THOROUGHLY INSPECT
VACUUM HOSE FOR ANY OBJECTS OBSTRUCTING
THE AIR FLOW.
4. RAISE SQUEEGEE AND WIPE BLADES WITH A CLEAN
CLOTH. STORE SQUEEGEE IN THE RAISED POSITION
TO PREVENT DAMAGE OR SETTING OF THE BLADES.
5. WIPE DOWN MACHINE IF NEEDED. USE A
NONABRASIVE, NON SOLVENT CLEANER, OR A
CLEAN DAMP CLOTH.
6. RECHARGE THE BATTERIES IF NEEDED.
WEEKLY MAINTENANCE
1. CHECK BATTERY WATER LEVEL IN EACH CELL OF THE
BATTERIES, AND FILL AS NEEDED. ALWAYS USE
DISTILLED WATER TO REFILL BATTERIES. BATTERIES
SHOULD BE FILLED APPROXIMATELY 3/4" TO 1" ABOVE
THE PLATES. OVERFILLING WILL CAUSE THE BATTERIES
TO LEAK DURING CHARGING. THE CHARGING
PROCESS CREATES GAS BUBBLES INSIDE THE BATTERY,
WHICH EFFECTIVELY INCREASES THE VOLUME OF THE
ELECTROLITE.
2. CLEAN BATTERY TOPS TO PREVENT CORROSION.
3. ROTATE BRUSHES. ROTATE THE LEFT TO THE RIGHT
AND RIGHT TO LEFT. ON CYLINDRICAL MODELS
FROM FRONT TO BACK, OR END TO END IF USING
DIFFERENT MATERIALS.
MONTHLY MAINTENANCE
1. CHECK SCRUB HEAD AND SQUEEGEE LIFTING CABLES
FOR WEAR AND SPRING TENSION.
2. CHECK MACHINE FOR WATER LEAKS AND LOOSE
NUTS AND BOLTS.
3. CHECK TO SEE IF BATTERY CABLES ARE TIGHTENED
(TIGHTEN IF NEEDED)
4. CHECK PARKING BRAKE
MAINTENANCE
SPECIFIC GRAVITY
@ 80
v
F (27
v
C)
BATTERY CONDITION
1.265
1.225
1.190
1.155
1.120
100% CHARGED
75% CHARGED
50% CHARGED
25% CHARGED
DISCHARGED
CHECKING BATTERY SPECIFIC GRAVITY
USE A HYDROMETER TO CHECK THE BATTERY
SPECIFIC GRAVITY.
CHECKING GRAVITY
A. HYDROMETER
B. BATTERY
NOTE: DO NOT TAKE READINGS IMMEDIATELY AFTER
ADDING DISTILLED WATER, IF WATER AND ACID ARE
NOT THOROUGHLY MIXED, THE READING MAY NOT
BE ACCURATE.
CHECK THE HYDROMETER AGAINST THIS CHART.
NOTE: IF THE READINGS ARE TAKEN WHEN THE
BATTERY ELECTROLYTE IS ANY TEMPERATURE
OTHER THAN 80
v
F (27
v
C), THE READING
MUST BE TEMPERATURE CORRECTED.
TO FIND THE CORRECTED SPECIFIC GRAVITY READING
WHEN THE TEMPERATURE OF THE BATTERY ELECTOLYTE
IS OTHER THAN 80
v
F (27
v
C): ADD (+) TO THE SPECIFIC
GRAVITY READING 0.004 (4 POINTS), FOR EACH 10
v
F
(6
v
C) ABOVE 80
v
(27
v
C).
SUBTRACT (-) FROM THE SPECIFIC READING 0.004
(4 POINTS), FOR EACH 10
v
F (6
v
C) BELOW 80
v
F (27
v
C).