VAC BOX SYSTEM
1. THE
"HIGH RECOVERY"
LIGHT
(RED)
WILL
ILLUMINATE
(A)
WHEN THE RECOVERY TANK IS
FULL. STOP IMMEDIATELY AND DRAIN RECOVERY
TANK.
(SEE FIGURE 25.)
FIGURE 25.
FIGURE 23.
2. IF RED LIGHT IS IGNORED THE VAC SWITCH
(B)
WILL
SHUT OFF VAC MOTORS AND SOUND HORN
(C
).
(SEE FIGURE 26.)
3. IF VAC IS PULLING EXCESSIVE CURRENT, CIRCUIT
BREAKER
(30 AMP)
(D)
MAY BLOW TO PREVENT
DAMAGE. IF THIS OCCURS CONTACT YOUR
SERVICE AGENT.
(SEE FIGURE 26.)
4. VAC SWITCH
(A)
IS SET TO ENGAGE AT 65" LIFT.
FIGURE 26.
5. IF FOAM OR WATER GETS PAST THE RECOVERY
TANK'S VAC SCREEN/BALL SYSTEM
(FIGURE 27.)
THE
"UNLOADER VALVE" (E)
WILL DRAIN IT FROM
THE VAC BOX.
6. "
UNLOADER VALVE" (E)
IS LOCATED ON THE
BOTTOM RIGHT SIDE OF THE VACUUM BOX.
(SEE FIGURES 24 & 28.)
SINGLE VAC SYSTEM
DUAL VAC SYSTEM
FIGURE 24.
D
C
B
FIGURE 27.
FIGURE 28.
PAGE 12