Model
Square
drive
Impact
rate
Recommended
dynamic
torque
Maximum
dynamic
torque
Noise level
Vibrations
level
m/s
2
Pressure dB(A)
Power dB(A)
Pressure dB(C)
‘‘
N.m
N.m
k*
k*
k*
k**
NK.2000F
3/4
1050
270 - 1220
1500
99,1
3
110,1
3
99,1
3
10,7
1,55
3/8 PT
Ø 13 mm
1/2 "
CE DECLARATION OF CONFORMITY
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
PRODUCT
NK.2000F – FACOM 3/4” AIR IMPACT WRENCH
- IS IN CONFORMITY WITH THE
«MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD
EN 792-6
:2000 +A1:2008
BS EN ISO 12100-1:2003+A1:2009
BS EN ISO 12100-2:2003+A1:2009
EN ISO 15744:2008
EN 28662-1:1993 &BS EN ISO 28927-2
20.01.2010
F
ACOM QUALITY MANAGER
CE DECLARATION OF CONFORMITY
WE FACOM S A S 6/8 RUE GUSTAVE EIFFEL BP 99 91 423 MORANGIS CEDEX FRANCE DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
Model
Free speed
Air consumption
Working pressure
Weight
Dimensions
rpm
l/min
bar
kg
mm
NK.2000F
5500
200
6,2
3,88
221 x 86 x 213
•
BEFORE EACH OPERATION, CHECK:
- Only use suitable FACOM sockets and flogging spanner accessories, (‘‘IMPACT’’)
as well as
safety devices, bush and pin for mounting one of these cases on a drilled driving
square.
- The drive square condition (no marks, cracks or excessive wear).
- The condition of the safety devices (bush and pin) on the drilled square as well as the draw
bead on the non-drilled square.
PLACING THE MACHINE IN SERVICE
EMERGENCY
GATE VALVE
* k = measurement uncertainty in dB
** k = measurement uncertainty in m/s²
LUBRIFICATION
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit:
FACOM N.581
.
Every eight hours’ operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
3
through the machine’s inlet connection.