Max*: 118” (3 m)
Venting Requirements
Page 5
Height & Clearance
Maximum* ceiling clearance
118” (3 m) at 33” (84 cm) hood
mounting height (may vary
with different model). Chimney
extensions available for higher
ceiling.
* Higher ceiling requires chim
-
ney extension. Available at
FABYKA
Min:
28” (71 cm)
Max: 33” (84 cm)
Vent system must terminate to the out-
side (roof or side wall).
Do not terminate the vent system in an
attic or other enclosed area.
Do not use 4” (10.2 cm) laundry-type
wall caps.
Use metal/aluminum vent only. Rigid
metal/aluminum vent is recommended.
Do not use plastic vent.
For the most efficient and quiet
operation:
It is recommended that the range hood
be vented vertically through the roof
through 8” (20 cm) round metal/ alumi
-
num vent work.
The size of the vent should be uniform.
Use no more than three 90° elbows.
Make sure there is a minimum of 24”
(61 cm) of straight vent between the
elbows if more than one elbow is used.
Do Not install two elbows together.
The length of vent system and number
of elbows should be kept to a minimum
to provide efficient performance.
The vent system must have a damper
on the roof or wall cap.
Use duct tape to seal all joints in the
vent system.
Use caulking or silicon to seal exterior
wall or roof opening around the cap.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Mounting
Bracket
Standard
Upper
Chimney
Extension available*
Standard
Lower
Chimney
Extension available*
Range hood
Base: 36” (90 cm)