Troubleshooting
Page 4
If the range hood does not operate after installa-
tion:
.
Check if the range hood has been plugged in, make
sure that all power has been turned back on and all
electrical wiring are properly connected.
Swap out light assembly to working ones to deter
-
mine whether it is caused by defective bulbs. (See
Replacing the light bulbs
, page 16)
•
•
The range hood vibrates when the blower is on:
.
The range hood might not have been secured prop
-
erly on to the ceiling.
•
The blowers seems weak:
3.
Check that the duct sized used is at least 8” (20
cm). Range hood WILL NOT function efficiently
with insufficient duct size. For example: 10” (25.4
cm) duct over 8” (20 cm) hole and loosely secured.
Check if duct is clogged or if damper unit is not
opening properly. A tight mesh on a side wall cap
unit might also cause restriction to the air flow.
•
•
The lights work but the blower is not spinning at
all, is stuck or is rattling.
4.
The blower might be jammed or scraping the bot
-
tom due to shipping damage.
•
The hood is not venting out properly:
5.
Make sure the distance between the cook top and
the bottom of the hood is within 28” (71 cm) and
33” (84 cm) in range.
Reduce the number of elbows and length of duct
work. Check if all joints are properly connected,
sealed, and taped.
Make sure the power is on high speed for heavy
cooking
•
•
•
NOTE:
For all other inquiries, please contact FABYKA’s customer service.