installation guide and user manual

free-standing gas fireplace

40 010 528

02 28

VICO

Saturnus 8

NL-8448 CC Heerenveen

Postbus 219

NL-8440 AE Heerenveen

T. +31(0)513 656500

F. +31(0)513 656501

“Log Burner Technology”

Содержание VICO

Страница 1: ...allation guide and user manual free standing gas fireplace 40 010 528 02 28 VICO Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 Log Burner Technology ...

Страница 2: ...the flue 18 5 2 Remote control 19 5 3 Installation 20 6 COMMISIONING 22 6 1 Check pilot ignition 22 6 2 Functional burner checkr 22 6 3 Functional balanced flue check 23 6 4 Check reference pressure 23 7 HANDING OVER 24 8 SERVICING 25 8 1 Routine annual servicing 25 U US SE ER R G GU UI ID DE E 33 9 SAFETY INSTRUCTIONS FOR THE USER 34 10 CONTROLING THE APPLIANCE 36 11 CLEANING AND SERVICE INSTRUCT...

Страница 3: ...distribution conditions identification of the type of gas and pressure and the adjustment of the appliance are compatible This gas appliance is factory set and shall not be adjusted by the installer This appliance does not contain any component manufactured from asbestos or any asbestos related products The pilot and flame sensing device fitted to this fire is also a safety device If for any reaso...

Страница 4: ...nd when installing the appliance Dimensions For the dimsensions see figure 1 Minimum distance between the appliance and rear wall is 50 mm and between appliance and sidewall min 250 mm A A 65 100 114 100 361 272 143 283 G3 8 72 30 322 1115 1155 250 min 50 min 478 542 224 ø150 ø100 470 A A fig 1 UK IRL 4 Building Regulations and Standards issued as relevant by the Department of the Environment or t...

Страница 5: ...ion is possible To establish this you will need to calculate The effective height this is the real difference in height between the upper side of the appliance and the terminal The total horizontal extension This is the total horizontal flue length where each elbow which is in the horizontal area counts for 2 meters each 45 degree bend which is in the horizontal area counts for 1 meter elbows and ...

Страница 6: ...he flue terminal is located within 2 meters of a footway path or where people could come into contact with it then a suitable terminal guard must be fitted Terminals located close to shared walkways footpaths etc could be subject to legal constraints and this should be pointed out to the customer before installation If in any doubt about flue location advice should be sought from local building co...

Страница 7: ... on n Balanced flue room sealed kW input 0 7 kW expressed in net Natural draught A Direct below an opening airbrick 300 mm opening windows etc B Above an opening airbrick 300 mm opening window ect C Horizontally to an opening airbrick 300 mm opening window etc D Below gutters soil pipes or drain pipes 500 mm E Below eaves 500 mm F Below balconies or car port roof 600 mm G From a vertical drain pip...

Страница 8: ... the appliance in the right position min distance 50 mm from rear wall and 250 mm from a side wall 2 Open the door by first loosening the locking screw in the door handle then pull down the handle See fig 4 locking A A fig 4 Example of how terminal position is measured UK IRL 12 ...

Страница 9: ...from the gas valve 5 Remove the cover plate see fig 6 Unfasten the 4 screws on both sides hold the ash pen tray horizontal while removing the cover plate 6 The connection should be made in 8 mm copper or similar semi flexible tube max 1 meter Ensure that the gas pipe does not interfere with the removal or replacement of the burner tray of the controls 7 The gas connection is nut and olive suitable...

Страница 10: ... or window Do not use the fire with broken or missing logs fig 8 4 2 Placing the appliance continuing 2 Points of attention for placement Locate the appliance before assembling the flue Painted flue pipes available see also chapter 5 Flue installation 3 Check if the safety hatch on top of the combustion chamber is in the right position and seals the combustion chamber properly it has to be air tig...

Страница 11: ...flue sections available for the flue run in the room Build the system starting from the appliance on Make a hole of ø 153 mm for the wall or roof mounted terminal Make sure you place the pipes in the right direction the narrow end towards the appliance Make sure the pipes are fixed sufficiently a wall clamp every 2m so the weight of the pipes is not resting onto the appliance The outside of the pi...

Страница 12: ...button on the remote control The control lamp on the receiver should now go out 5 Again push a button on the remote control The lamp starts flashing and will switch off eventually 6 The receiver now recognizes the remote control The remote control now functions 7 Check if you can hear a sound and the motor runs when you push a button on the remote control 5 3 Installation remote control 1 Connect ...

Страница 13: ...w Re light the appliance Turn to max input and test around the test point D for gas soundness using a suitable leak detection fluid C D D C A B B A fig 12 6 COMMISSIONING functional checks 6 1 Check pilot ignition 1 Push in and turn the control knob A from anticlockwise to the setting small flame You will hear a tick meaning there is ignition Hold the knob in and wait for a few seconds while the a...

Страница 14: ...servicing 1 Clean if necessary the pilot system the burner the combustion chamber the glass 2 Check the log lay and replace the embers if applicable 3 Do the functional test as described at page 22 4 Check the flue system and terminal on damage and soundness visual inspection 7 HANDING OVER final check and customer briefing 7 7 1 1 Instruct the customer on the full operation of the appliance 7 7 2...

Страница 15: ...ou can get a deposit on the glass This can be removed with a special ceramic glass cleaner ceramic cook top cleaner as follows 1 Open the door as described at 4 1 2 Clean the glass Handle the glass with clean hands wear gloves if possible try to avoid fingerprints on the glass 3 Close the door and fixate the door handle A At tt te en nt ti io on n Before closing the door check the sealing rope is ...

Страница 16: ...hin 30 minutes 100ppm CO per 1 CO2 A reading of CO in the room centre should give a rise of less than 9ppm over ambient peak reading Gas control block A Governor B Adjusting screw pilot flame C Inlet pressure test point D Burner pressure test point Propane conversion For conversion from propane to natural gas order for a propane burner unit Please give the serial number from the data plate when yo...

Страница 17: ...CHNICAL DATA VICO Country UK IRL UK IRL Category II2H3 II2H3 Appliance type C11 C31 C11 C31 Reference gas G20 G30 G3 Input nett kW 7 1 6 9 Efficiency class 2 2 Inlet pressure mbar 20 30 37 Gas Rate 15 C 1013 mbar m3 h 0 75 0 215 or 0 5 kg Reference burner pressure mbar 12 23 Injector size mm 3x 1 5 3x 0 9 Reduced input restrictor mm 2 1 1 1 Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30 Flue...

Страница 18: ...UK IRL 33 USER GUIDE UK IRL 32 ...

Страница 19: ... co on nt ta ac ct t y yo ou ur r i in ns st ta al ll le er r o or r g ga as s e em me er rg ge en nc cy y s se er rv vi ic ce e T Th he es se e i in ns st tr ru uc ct ti io on ns s s sh ho ou ul ld d b be e r re ea ad d c ca ar re ef fu ul ll ly y a an nd d r re et ta ai in ne ed d f fo or r f fu ut tu ur re e r re ef fe er re en nc ce e D Do o n no ot t u us se e t th he e f fi ir re e w wi it t...

Страница 20: ...er ten seconds to ensure that the pilot flame is stable 3 Release the knob The pilot should remain alight 4 Turn the control knob A to the position 5 Turn knob B slowly anticlockwise the fire should then ignite 6 Adjust flames to the required level 10 CONTROLLING THE APPLIANCE 10 1 Lighting the fire If the main burner or pilot light are extinguished for any reason d do o n no ot t a at tt te em mp...

Страница 21: ...e to position 2 To disable knob B turn knob A to the position 3 To extinguish the pilot turn control knob A to position although it is in order lo leave the pilot permanently lit 10 3 1 When the pilot extinguishes W Wa ar rn ni in ng g When the pilot extinguishes for whatever reason you should wait at least 5 minutes before trying to turn it on again Possible causes of pilot extinguish are Operati...

Страница 22: ... waste and should be disposed in accordance with local regulations AAA A A A fig 17 changing batteries 10 4 3 Setting the right transmission code The receiver has to learn the code from the transmitter which is already done at the factory However the code disappears if the receiver is disconnected from the mains for a longer period 1 Set the on off switch on the receiver to on 2 Push the mod butto...

Страница 23: ...es before disposing of the remote control Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities 11 CLEANING AND SERVICE INSTRUCTIONS I Im mp po or rt ta an nt t T Tu ur rn n o of ff f t th he e f fi ir re e a an nd d a al ll lo ow w i it t t to o c co oo ol l d do ow wn n b be ef fo or re e c co om mm me en nc ci in ng g c cl le ea an ni in ng...