Dear user
1
Congratulations on purchasing your Faber product,
a quality product that will provide you with the
warmth and atmosphere for many years. Please
read the user manual before using the fire. Should,
despite the careful final checks, a malfunction
occur, please contact your Faber dealer.
Please note:
The data of your fire is available in the user
manual.
Introduction
1.1
Only have the appliance installed by a qualified
installer according to the gas safety regulations.
Read this installation manual properly.
Please check
1.2
Check the fire for transport damage and report any
damage immediately to your dealer.
Check that the following parts are included:
1.
Decoration material
2.
Cover Ionisation plug .(fig.3.1 a)
3.
Suction Cups
4.
warranty card
5.
User’s manual
6.
Installation manual
7.
Instruction card for decoration material
8.
Remote controller
9.
ranges of restrictors (fig.4.2)
10.
Set long legs (fig.1.2 c )
11.
Decorative solid cover trims (method 1
and 2) and integrated cover trim Q
(Method 3) (fig. 2.1a tm 2.1 c)
12.
magnet snapper (fig.2.1R)
CE Declaration
1.3
Glen Dimplex Benelux certifies that this Faber fire
complies with the essential requirements of the
gas appliances directive.
Product: gas room heater
Model: Triple Premium XXL
Applicable EC directives: 90/396/EEC
Harmonised standards applied: NEN-EN-613
NEN-EN-613/A1
This Declaration is invalid, if without the written
permission of Glen Dimplex Benelux:
Changes are made to the appliance.
The fire is connected to other exhaust
materials than specified.
Safety instructions
2
The unit must be installed and subsequently
serviced every year and maintained in
accordance with these instructions and the
applicable national and local regulations.
Ensure that the data on the type label matches
the local gas type and pressure.
The settings and the construction of the fire
must not be changed!
The 230V electric cable may be only replaced
by a qualified person.
Ensure that the log layout (if applicable)
exactly matches the relevant photographs in
the instruction leaflet and never add extra
decorative material that was not supplied with
the fire.
The pilot flame must never be obstructed and
particular care must be taken when placing
the logs, pebbles or stones which are supplied
with the fire.
The unit is for atmosphere and heating
purposes. This means that all surfaces,
including the glass, can be very hot (over
100°C); exceptions to this are the bottom of
the fire and the control elements.
Do not place any combustible materials within
0.5m of the radiation area of the fire.
Before use, remove all stickers, protective film
and any protective rubber strips from the
glass.
Ensure adequate ventilation of the room when
using the fire for the first time. Run the fire at
the highest setting for several hours so that
the paint will have the chance to harden and
any possible vapours can be released safely.
Keep children and pets out of the room during
this process.
Please note
Through the natural air circulation of the fire
moisture and uncured volatile components
from paint, building materials and carpeted
floors, etc. are attracted. These parts can
settle as soot on cold surfaces. Therefore do
not light the fire shortly after installation
.
Содержание Triple Premium XXL
Страница 1: ...Triple Premium XXL 40011590 1529 Triple Premium XXL ENG ...
Страница 2: ...Installatie handleiding 2 1 1 1 2 1 3 1 4 1 5 1 6 C ...
Страница 3: ...Installatie handleiding 3 1 7 1 8 1 9 2 1 a 2 1 b 2 1 c 2 1 d C ...
Страница 4: ...Installatie handleiding 4 2 2 2 3 2 4 2 5 2 7 2 8 2 9 H F F X C X T S A ...
Страница 5: ...Installatie handleiding 5 3 1 3 1 a 3 1 b 3 1 c ...
Страница 6: ...Installatie handleiding 6 4 1 4 2 5 1 a 5 1 b 5 1 c 5 1 d 5 1 e ...
Страница 17: ...Installatie handleiding 17 Example 12 fig 12 1 fig 1 2 2 fig 12 3 ...
Страница 23: ...Installatie handleiding 23 Drawings 16 Triple Premium XXL 16 1 ...
Страница 24: ...Installatie handleiding 24 Builder s opening and control box dimensions 16 2 ...
Страница 25: ...Installatie handleiding 25 Builder s opening and ventilation grills dimensions 16 3 ...
Страница 26: ......