Installatie handleiding
13 <
<
<
<
the batteries and how to “pair” the remote
control and ITC.
Handing over to the customer
8.1
Installation instruction.
User manual.
ITC operation instruction.
Warranty card.
log layout instruction card.
Remote control handset.
Suction cups.
Magnetic snapper.
Annual maintenance
9
Checking and cleaning:
9.1
Check and where necessary, clean
o
Ignition to the main burner.
o
Ionisation.
o
The burner.
o
The combustion chamber.
o
The glass.
o
The ceramic logs for breakages.
o
The terminal.
Replace, if necessary:
o
Decoration material / Glow-wire.
Cleaning the glass
9.1.1
Most deposits can be removed with a dry cloth but
if necessary a ceramic hob cleaner. Can be used.
Please note:
Avoid fingerprints on the glass. These may be
burnt on by the heat and then no longer be
removable
Conversion to another gas type
10
The conversion to a different gas type may only be
performed by a qualified installer/dealer.
Conversion from natural gas to
10.1
propane (or vice versa)
This can only be done by replacing the burner. To
do so, please contact your dealer.
Specify with your order always the type and serial
number of the device.
Flue calculation
11
The quickest and simplest way to calculate
whether your chosen flue configuration is possible
in combination with your fire, is to use the free
“Faber Flue App” which can be download from:
INTERNET:
BlackBerry, Android, PC (with Google Chrome
browser)
APP store:
iPhone, iPad and Mac.
Google Play:
Android smartphones and Android tablets.
Alternatively use the flue calculation table (see
tables below and sections 12 and 13).
The alternatives of outlet lengths and any
restrictors are set out in the restrictor table. In the
table we work with Start Length (STL) Total Vertical
Height (TVH) and Total Horizontal Length (THL).
Start Length (STL)
This is the first pipework component that is placed
on the fire and is shown as length in metres (Fig.
12.1, 12.2 and 12.3 A, N, F).This value is in the top
row of the table (see table).
Total Vertical Height (TVH)
TVH is the difference in height measured from the
top of the fire to the end of the outlet; it can be
measured or determined from the building plan.
For clarification see the TVH indication in the
drawings. (Fig. 12.1, 12.2 and 12.3: TVH)
Total Horizontal Length (THL)
THL is the Total Horizontal Length and consists of
elbows and pipes used entirely in the horizontal
plane. Elbows I, K and Q and the elements H, J, L,
M, P and R (Fig. 12.2 and 12.3).
Horizontal length
The horizontal length consists of the elements H, J,
L, M, P and R (Fig. 12.2 and 12.3).
bends 90° in the horizontal plane
Bends used entirely in the horizontal plane (Fig.
12.1, 12.2 and 12.3 I, K and Q).
Bends 45° or 30° in the horizontal plane
Bends used entirely in the horizontal plane
90° Bends
Содержание Triple Premium XXL
Страница 1: ...Triple Premium XXL 40011590 1529 Triple Premium XXL ENG ...
Страница 2: ...Installatie handleiding 2 1 1 1 2 1 3 1 4 1 5 1 6 C ...
Страница 3: ...Installatie handleiding 3 1 7 1 8 1 9 2 1 a 2 1 b 2 1 c 2 1 d C ...
Страница 4: ...Installatie handleiding 4 2 2 2 3 2 4 2 5 2 7 2 8 2 9 H F F X C X T S A ...
Страница 5: ...Installatie handleiding 5 3 1 3 1 a 3 1 b 3 1 c ...
Страница 6: ...Installatie handleiding 6 4 1 4 2 5 1 a 5 1 b 5 1 c 5 1 d 5 1 e ...
Страница 17: ...Installatie handleiding 17 Example 12 fig 12 1 fig 1 2 2 fig 12 3 ...
Страница 23: ...Installatie handleiding 23 Drawings 16 Triple Premium XXL 16 1 ...
Страница 24: ...Installatie handleiding 24 Builder s opening and control box dimensions 16 2 ...
Страница 25: ...Installatie handleiding 25 Builder s opening and ventilation grills dimensions 16 3 ...
Страница 26: ......