background image

 

Installation manual Relaxed M,L Smart

 

 

10 < 

<

 

<

 

7.1

 

Checking the flame image 

Let the fireplace burn for at least 20 minutes at 
highest setting and check the flame for:  

 

flame distribution;  

 

colour of the flames. 
 

If one or both points are not acceptable then 
check:  

 

The position of the logs and/or the 
amount of ash material. 

 

The pipe connections for leaks. 
(in case of blue flames);  

 

That the correct flue restrictor is fitted 
(see fig. 2.5);  

 

The outlet:  

o

 

Wall terminal has the correct 
position and side up; 

o

 

Roof terminal has the correct 
position. 

 

If the maximum lengths of the flue gas 
outlet is not exceeded. 

8

 

Instructions for client 

 

Recommend that the fire should be 
checked annually by a qualified specialist 
to ensure the safe use and to guarantee a 
long service life.  

 

Provide instructions on the operation of: 

o

 

the appliance; 

o

 

the remote control; 

o

 

if present, the App and its 
settings. 

 

Give advice and instructions on care and 
cleaning of the glass: 

 

 

Emphasize the danger of fingerprint burns 
at the glass. 

 

Handover to customer: 

o

 

installation manual;  

o

 

user manual; 

o

 

decoration instruction card; 

o

 

suction cups; 

o

 

sample Faber glass polish. 

 
 
 
 
 
 
 

9

 

Annual maintenance 

 
Check
 
Check and clean if necessary: 

 

the combustion chamber; 

 

the burner 

 

the pilot flame; 

 

the wooden logs for breakage; 

 

the glass(es); 

 

the outlet. 

 
Replace ash material  if necessary. 
 
Cleaning 
Remove the front glass (see chapter 5). 
You can clean the glass with Faber glass polish.  
This is a specially formulated cleaning agent that 
can be ordered at authorized Faber dealers. 
Never use aggressive cleaning agents or abrasive 
products. 
 

 

Please note! 
Avoid fingerprints on the glass; these are no 
longer removable once the fire is used. 

 
Now carry out check-up as described in chapter 7. 
 
For an extensive maintenance instruction 
"maintenance protocol gas fires" see: 

 

10

 

Conversion to other gas type 

This can only be done by replacing the burner. To 
do so, please contact your dealer. Always provide 
the type and serial number of the appliance when 
ordering. 
 

 

Содержание Relaxed M Smart

Страница 1: ...Installation manual Relaxed M Smart Relaxed L Smart ENG 40010635 2010...

Страница 2: ...Installation manual Relaxed M L Smart 1...

Страница 3: ...Installation manual Relaxed M L Smart 2...

Страница 4: ...Installation manual Relaxed M L Smart 3 1 1 1 2 1 3 1 4 1 5 1 6...

Страница 5: ...Installation manual Relaxed M L Smart 4 1 7 2 0 2 1 2 2 2 3 2 4 2 5 A C B 1 2...

Страница 6: ...Installation manual Relaxed M L Smart 5...

Страница 7: ...e note It is advisable to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present...

Страница 8: ...he flue material EN 1856 1 T600 N1 D Vm L20040 O 50 Outlets fig 1 5 The balanced flue pipe for combined air supply and discharge can use a wall terminal or a roof terminal Verify that the desired outl...

Страница 9: ...parts from the fireplace Prepare the gas connection on the gas valve 4 5 Positioning the fireplace Take into account the installation requirements see chapter 3 Place the fireplace at the right place...

Страница 10: ...terial on the burner at once It is possible that the burner gets clogged See the supplied decoration instruction card or chapter 18 1 or 18 2 Place part of the ash material at the burner and the cover...

Страница 11: ...d instructions on care and cleaning of the glass Emphasize the danger of fingerprint burns at the glass Handover to customer o installation manual o user manual o decoration instruction card o suction...

Страница 12: ...pes entirely in the horizontal plane See elbows I K and Q and the elements H J L M P and R fig 12 1 and 12 2 Horizontal length The Horizontal Length consists of the elements H J L M P and R fig 12 1 a...

Страница 13: ...0 00 30 00 0 00 x x x x 12 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 13 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 14 65 00 65 00 50 00 50 00 40 00 30 00 30 00 x x x x 15 65 00 65 00 50...

Страница 14: ...60 00 50 00 50 00 40 00 30 00 x x x x 12 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 13 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 14 65 00 65 00 60 00 50 00 50 00 40 00 30 00 x x x x 15...

Страница 15: ...Installation manual Relaxed M L Smart 14 12 Examples flue materials...

Страница 16: ...5 Flue length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation...

Страница 17: ...installation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installati...

Страница 18: ...ass B B B Energy efficiency index EEI 85 85 85 Type heating output control room temperature no no no no yes no Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the...

Страница 19: ...ergy efficiency index EEI 84 84 84 Type heating output control room temperature no no no no yes no Diameter outlet inlet 100 150 Technical data Type indication s Relaxed Smart L Type appliance C11 C31...

Страница 20: ...ition outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 100...

Страница 21: ...Installation manual Relaxed M L Smart 20 16 Troubleshooting guide...

Страница 22: ...Installation manual Relaxed M L Smart 21...

Страница 23: ...Installation manual Relaxed M L Smart 22 17 Dimensional drawings 17 1 Relaxed M Smart...

Страница 24: ...Installation manual Relaxed M L Smart 23 17 2 Relaxed L Smart...

Страница 25: ...Installation manual Relaxed M L Smart 24 17 3 Remote access door A9299463...

Страница 26: ...Installation manual Relaxed M L Smart 25 17 4 Ventilation grid article number A9296400...

Страница 27: ...Installation manual Relaxed M L Smart 26 18 Decoration instruction card 18 1 Log set Relaxed M Smart...

Страница 28: ...Installation manual Relaxed M L Smart 27 18 2 Log set Relaxed L Smart...

Страница 29: ...Installation manual Relaxed M L Smart 28...

Страница 30: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen...

Отзывы: