IRL

 
 

3.3

 

Requirements flue system and outlets 

 

Top outlet 
The flue connector collar is for connection to 

a 125 mm (5 inch) internal diameter pipe or 
liner according BS EN 1856. 

The minimum effective height of the flue 
system must be 3 meter. 

 
Rear outlet 

In case of an installation in a masonry 
chimney convert the outlet to the rear outlet. 

Therefore unscrew the top outlet and fit the 
rear outlet on the fire. Take care to fill up all 

the holes with the screws.(see fig.1.3) 
 

To collect the debris, there must be a 
minimum gap of 23 mm behind the appliance 
Use the supplied glass fibred-seal to seal the 

fire box to the builders opening.(see fig.1.2) 
 

Chimney 
The top of the chimney must always be higher 

then the top of the roof. 
 

 

4

 

Preparation and Installation 
instructions  

 

4.1

 

Gas connection 

The gas connection must comply with locally 

valid standards. 
We advise Pipe work from the meter to the 

appliance must be of adequate size. An 
isolator is factory fitted, no further isolation 

device is required. Place the gas connection 
in such a way that it is accessible for service 

and the burner unit can be disconnected at all 
times. 

 
4.2

 

Preparation of the appliance  

 

Remove the packaging of the 

appliance. 

 

Clear a safe space to store the glass. 

 

Remove the glass (see chapter 5) and 
take the separately wrapped parts out 

of the appliance. 

 

Prepare the gas connection. 

 

Prepare the flue connection. 

 

If necessary convert to rear outlet 
(see chapter 3.3). 

 

If necessary convert to framed 
version. 

Therefore: 
A.

 

Remove the build in frame (see 

fig.3.1) 

B.

 

Fit the frame support. (see 

fig.3.2) 

C.

 

The frame now can be hung on 
the support. (see fig.3.3) 

 
4.3

 

Batteries. 

The battery pack is fixed on a chain inside the 
burner unit on the right side. (see fig.2.2) 

Pull the chain to remove it. 
To avoid overheating take care that the 

battery pack always is positioned correctly 
in the burner unit. 

 
4.4

 

Placing the appliance  

Take the installation requirements into 
account (see chapter 3). 

 
Masonry chimney 

Cut out the opening so that the appliance can 
be fitted easily. 

 
prepare the 2 non combustible supports on 
the left and the right side in the builders 

opening (see fig. 1.1) 
 

For a Top outlet connection  
Pull a 5 inch liner into the chimney. 

Fit the fire in the builders opening and 
connect the liner on the top outlet. 

 
For a Rear outlet installation 

Fit the fire in the builders opening, use the 
supplied glass fibred-seal to seal the fire box 

to the builders opening.(see fig.1.3) 
 

Do a gas leakage test on all joints and check 
burner and inlet pressure. 

See chapter 7 before closing the chimney  
 

Reconstruct the wall of the chimney. 
 

 

5

 

Removing the glass 

 

 

Place the suction discs onto the glass  

 

Remove the cover strips on the left 
and right side by pushing the top (see 

fig.1.4) 

 

Remove the cover strips on the left 

and right hand side (see fig.1.5) 

 

Remove the sealing cord from the 

groove (see fig.1.6) 

 

Lift the glass up and move slowly 
forward, now you can take the glass 

out.  

 

To replace the glass repeat the process in 
reverse order. 

Remove all Fingerprints from the glass, these 
will be burned into it once the hearth is used. 

 
 

Содержание Presence

Страница 1: ...Presence Installation Guide and users manual GB IE GB IE 40011221 1138 ...

Страница 2: ...1 UK IRL Installation Guide ...

Страница 3: ...2 UK IRL 1 1 1 2 1 3 1 4 1 5 1 6 ...

Страница 4: ...3 UK IRL 1 7 1 8 2 1 2 2 2 3 2 4 2 5 ...

Страница 5: ...4 UK IRL 2 6 3 1 3 2 3 3 4 1 4 2 A B ...

Страница 6: ...ion The first time the appliance is switched on Let the fire run on maximum setting for several hours so that the lacquer coating will have an opportunity to set and possible vapours released can be safely removed by ventilation We advise you to be outside the room as much as possible during this process Please note that 1 all transport packaging should be removed 2 children or pets should not be ...

Страница 7: ... If necessary convert to framed version Therefore A Remove the build in frame see fig 3 1 B Fit the frame support see fig 3 2 C The frame now can be hung on the support see fig 3 3 4 3 Batteries The battery pack is fixed on a chain inside the burner unit on the right side see fig 2 2 Pull the chain to remove it To avoid overheating take care that the battery pack always is positioned correctly in ...

Страница 8: ...hecking for gas leakage Check all connections and joints for possible gas leaks by means of a gas leak detector or spray 7 3 Checking the burner pressure and the inlet pressure Check whether the burner pressure and the inlet pressure measured agree with the data indicated on the registration plate 7 4 Measuring the inlet pressure Turn off the gas control Get access to the burner unit by removing t...

Страница 9: ...sed and cannot be removed anymore 8 4 Check and cleanup debris To get access to the debris area remove the 1 glass see chapter 5 2 log set 3 burner unit Therefore Remove the bottom plates in the front and at the back see fig 2 3 Unscrew 4 screws 2 at the left and 2 at the right and remove the burner plate including the burner see fig 2 4 Disconnect the gas Unscrew 13 screws of the burner unit and ...

Страница 10: ...7 Gas rate at 15ºC and 1013 mbar l h 542 150 181 Gas rate at 15ºC and 1013 mbar gr h 380 340 Burner pressure at full mark mbar 9 5 20 25 7 Injector main burner mm 2 1 1 3 1 3 Minimum screw mm 1 3 0 85 0 85 Pilot assembly OP9030 OP9222 OP9222 Diameter outlet mm 125mm 5 inch 125mm 5 inch 125mm 5 inch Gas control valve GV60 GV60 GV60 Gas connection 8mm 8mm 8mm Batteries receiver V 4x AA 1 5V 4x AA 1 ...

Страница 11: ...10 UK IRL 11 Dimensions Presence Frameless Top outlet ...

Страница 12: ...11 UK IRL 12 Dimensions Presence Frameless Rear outlet ...

Страница 13: ...12 UK IRL 13 Dimensions Presence Framed Top outlet ...

Страница 14: ...13 UK IRL 14 Dimensions Presence Framed Rear outlet ...

Страница 15: ...14 UK IRL Users manual ...

Страница 16: ...15 UK IRL 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 ...

Страница 17: ...16 UK IRL 1 9 2 0 2 1 2 2 2 3 2 4 2 5 ...

Страница 18: ...aterials in the combustion chamber Never change the position of the log set and never add more decorative materials or carrara pebbles than have been supplied with the appliance If the fire is switched on the pilot light should always be visible Don t place any curtains clothes laundry furniture or other inflammable materials in the neighbourhood of the appliance The minimum safe distance is 100 c...

Страница 19: ...2 2 Wait or press the OFF key to terminate this function fig 2 0 19 2 Setting the transmitter code on the remote control unit Press the reset button of the receiver with a pointed object until the second signal is audible Now press the key on the remote control unit fig 2 1 within 20 seconds If a sound signal is audible the transmitter code has been set 19 3 Temperature clock setting standard C 24...

Страница 20: ...of the periods for day and night temperatures is set within 24 hours 21 2 Setting day and night temperatures Move the SET key fig 1 8 step by step to ÏTEMP Now keep the SET key fig 1 8 pushed in for a long time until the temperature indication in the display screen starts to blink In accordance with your wishes increase the Day temperature with the key fig 2 1 or lower it with the key fig 2 2 Pres...

Страница 21: ... or wait for ten seconds 22 Checkpoints in case of Malfunction If the remote control unit of the fire does not function properly check the following points first 1 Is the toggle switch fig 1 1 set to position I 2 Check the battery chapter 18 5 3 Check whether the receiver responds to the remote control unit If necessary reset the receiver Therefore Briefly pull the battery pack out and remove the ...

Страница 22: ...21 UK IRL ...

Страница 23: ...22 UK IRL ...

Страница 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: