Faber Presence Скачать руководство пользователя страница 18

 

17 

<

 

<

 

<

 

<

 

UK

IRL

15

 

Introduction 

 

Because this appliance is a source of heat, air 
circulation will arise. That is why it is 

important that you do not use the fire shortly 
after a renovation. By natural air circulation 

moisture and volatile components from paint, 
building materials, floor coverings etc. that 

haven’t set yet, are sucked up. These 
components can be deposited on cold surfaces 

as soot. The first time you should use the fire 
depends on various circumstances. Consult 
your gas fitter on this matter. 

 
 

16

 

Cleaning and Maintenance 

 

 

The appliance will have to be cleaned 
and serviced and the proper 
functioning checked by a gas fitter. 

 

The outside frame of the fire can be 
cleaned with a clean damp cloth. 

 
16.1

 

Cleaning the glass 

 

Dismount the glass according to the 
description in the installation 

instructions. 

 

Remove the deposit with a clean dry 

cloth. If necessary, a special ceramic 
cleaning agent can be used. 

Note:  prevent the making of finger marks on 
the glass. These cannot be removed once the 
fire has burnt them into the glass! 

 
 

17

 

Safety Instructions for the User 

 

 

The appliance has been designed for 
atmospheric and heating purposes. This 
means that all surfaces of the fire, 

including the glass, can become very hot 
(hotter than 100 °C). An exception to this 

is the on-off switch of the fire  

 

If the fire has been switched off, wait for 

at least three minutes before re-igniting 
it again. 

 

If the fire switches off with no known 
cause, wait for at least 15 minutes 

before re-igniting the fire again. If this 
happens repeatedly, get in touch with 

your gas fitter. 

 

The fire should not be used if: 

The glass is damaged or has been 

removed. 

The combustion chamber is open. 

 

Don’t place any inflammable materials 
in the combustion chamber. 

 

 Never change the position of the log set 

and never add more decorative 

materials or carrara pebbles than have 
been supplied with the appliance. If the 

fire is switched on, the pilot light should 
always be visible! 

 

Don’t place any curtains, clothes, 
laundry, furniture or other inflammable 

materials in the neighbourhood of the 
appliance. The minimum safe distance is 

100 cm. 

 

Don’t allow children to use the remote 

control unit without adult supervision. 

 

Fit a suitable fireguard if there are 
children, old people or persons with 

limited mobility present in the same 
room. 

 
 

18

 

First time the fire is operated 

 

Before ignition, remove all stickers, 

protective wrappings and, if present, rubber 
protective padding from the glass. 

Make sure the room is properly ventilated the 
first time the fire is switched on. Burn the 

appliance at the highest position for some 
hours so that the lacquer coating will have an 

opportunity to set and possible vapours 
released can be safely removed by 

ventilation. Keep children and pets outside 
the room during this process! 

 
18.1

 

Remote control unit – general remarks 

The appliance has been supplied with a 
remote control set; The receiver and the gas 

control are located underneath the burner.  
Access only allowed by a competent person  

 

The remote control has been provided 
with 3 keys (fig.1.4). All functions of 

the fire can be operated with these 
keys. 

 

If the transmission is successful, the 

receiver will emit a sound signal. 

 

With the On/Off switch (fig. 1.1) the 

fire can always be switched off. 

 

Switch in O position –, if the fire is 

not in use for a longer period. 

 

When using the thermostat/timer 

function, the wall bracket supplied 
(fig. 2.3/2.4/2.5) should always be 
placed within 4 metres of the 

appliance . 

 

18.2

 

batteries 

The battery pack for the receiver is fixed on a 

chain and store on the right side underneath 
the burner unit. (see fig. 1.3) 

 

Содержание Presence

Страница 1: ...Presence Installation Guide and users manual GB IE GB IE 40011221 1138 ...

Страница 2: ...1 UK IRL Installation Guide ...

Страница 3: ...2 UK IRL 1 1 1 2 1 3 1 4 1 5 1 6 ...

Страница 4: ...3 UK IRL 1 7 1 8 2 1 2 2 2 3 2 4 2 5 ...

Страница 5: ...4 UK IRL 2 6 3 1 3 2 3 3 4 1 4 2 A B ...

Страница 6: ...ion The first time the appliance is switched on Let the fire run on maximum setting for several hours so that the lacquer coating will have an opportunity to set and possible vapours released can be safely removed by ventilation We advise you to be outside the room as much as possible during this process Please note that 1 all transport packaging should be removed 2 children or pets should not be ...

Страница 7: ... If necessary convert to framed version Therefore A Remove the build in frame see fig 3 1 B Fit the frame support see fig 3 2 C The frame now can be hung on the support see fig 3 3 4 3 Batteries The battery pack is fixed on a chain inside the burner unit on the right side see fig 2 2 Pull the chain to remove it To avoid overheating take care that the battery pack always is positioned correctly in ...

Страница 8: ...hecking for gas leakage Check all connections and joints for possible gas leaks by means of a gas leak detector or spray 7 3 Checking the burner pressure and the inlet pressure Check whether the burner pressure and the inlet pressure measured agree with the data indicated on the registration plate 7 4 Measuring the inlet pressure Turn off the gas control Get access to the burner unit by removing t...

Страница 9: ...sed and cannot be removed anymore 8 4 Check and cleanup debris To get access to the debris area remove the 1 glass see chapter 5 2 log set 3 burner unit Therefore Remove the bottom plates in the front and at the back see fig 2 3 Unscrew 4 screws 2 at the left and 2 at the right and remove the burner plate including the burner see fig 2 4 Disconnect the gas Unscrew 13 screws of the burner unit and ...

Страница 10: ...7 Gas rate at 15ºC and 1013 mbar l h 542 150 181 Gas rate at 15ºC and 1013 mbar gr h 380 340 Burner pressure at full mark mbar 9 5 20 25 7 Injector main burner mm 2 1 1 3 1 3 Minimum screw mm 1 3 0 85 0 85 Pilot assembly OP9030 OP9222 OP9222 Diameter outlet mm 125mm 5 inch 125mm 5 inch 125mm 5 inch Gas control valve GV60 GV60 GV60 Gas connection 8mm 8mm 8mm Batteries receiver V 4x AA 1 5V 4x AA 1 ...

Страница 11: ...10 UK IRL 11 Dimensions Presence Frameless Top outlet ...

Страница 12: ...11 UK IRL 12 Dimensions Presence Frameless Rear outlet ...

Страница 13: ...12 UK IRL 13 Dimensions Presence Framed Top outlet ...

Страница 14: ...13 UK IRL 14 Dimensions Presence Framed Rear outlet ...

Страница 15: ...14 UK IRL Users manual ...

Страница 16: ...15 UK IRL 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 ...

Страница 17: ...16 UK IRL 1 9 2 0 2 1 2 2 2 3 2 4 2 5 ...

Страница 18: ...aterials in the combustion chamber Never change the position of the log set and never add more decorative materials or carrara pebbles than have been supplied with the appliance If the fire is switched on the pilot light should always be visible Don t place any curtains clothes laundry furniture or other inflammable materials in the neighbourhood of the appliance The minimum safe distance is 100 c...

Страница 19: ...2 2 Wait or press the OFF key to terminate this function fig 2 0 19 2 Setting the transmitter code on the remote control unit Press the reset button of the receiver with a pointed object until the second signal is audible Now press the key on the remote control unit fig 2 1 within 20 seconds If a sound signal is audible the transmitter code has been set 19 3 Temperature clock setting standard C 24...

Страница 20: ...of the periods for day and night temperatures is set within 24 hours 21 2 Setting day and night temperatures Move the SET key fig 1 8 step by step to ÏTEMP Now keep the SET key fig 1 8 pushed in for a long time until the temperature indication in the display screen starts to blink In accordance with your wishes increase the Day temperature with the key fig 2 1 or lower it with the key fig 2 2 Pres...

Страница 21: ... or wait for ten seconds 22 Checkpoints in case of Malfunction If the remote control unit of the fire does not function properly check the following points first 1 Is the toggle switch fig 1 1 set to position I 2 Check the battery chapter 18 5 3 Check whether the receiver responds to the remote control unit If necessary reset the receiver Therefore Briefly pull the battery pack out and remove the ...

Страница 22: ...21 UK IRL ...

Страница 23: ...22 UK IRL ...

Страница 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: