Faber Presence Скачать руководство пользователя страница 6

 

<

 

<

 

<

 

<

 

UK

IRL

1

 

Introduction 

 
The fire can only be installed by a competent 

person in accordance with the Gas Safety 
Installation and Use regulations. We urgently 
advise you to read this installation manual 

properly. 
This appliance complies with the guidelines 

for European gas appliances (Gas Appliances 
Directive) and bears the CE mark. 

 
 

2

 

Safety instructions. 

 

 

The appliance should be placed, 

connected and annually checked in 
accordance with these installation 

instructions and valid national and 
local Gas Safety (Installation and Use) 

Regulations . 

 

Check whether the data on the 

registration plate are in agreement 
with the local type of domestic gas 
and pressure.  

 

It is not permitted to change the 
adjustments or the construction of 

the appliance! 

 

Do not place any additional imitation 

logs or glowing coals on the burner or 
in the combustion chamber. 

 

The appliance has been designed for 
ambience and heating purposes. This 

means that all surfaces of the 
appliance , including the glass, can 

become very hot (hotter than 100 
°C). An exception to this are the 
bottom of the appliance and the 

controls. 

 

Do not place any combustible 

materials within 0.5 m. of the 
radiation of the appliance and 

ventilation grills.  

 

Due to natural air circulation of the 

appliance, moisture and volatile 
components from paint, building 

materials, floor coverings etc. that 
haven’t yet set, can be drawn through 

the convection system and can be 
deposited on cold surfaces as soot. 

That is why you should not use the 
appliance shortly after a renovation. 

 

The first time the appliance is 
switched on, Let the fire run on 
maximum setting for several hours so 

that the lacquer coating will have an 
opportunity to set and possible 

vapours released can be safely 
removed by ventilation. We advise 

you to be  outside the room as much 
as possible during this process! 

 

Please note that: 

1.

 

all transport packaging should be 
removed.  

2.

 

children or pets should not be 
present in the room. 

 

No extra ventilation is required, due 
to the fact that the input of the 

appliance is not exceeding 7,0 kW. 

 

 

3

 

Installation requirements 

 

3.1

 

The fire  

The fire is tested for installation without a 

hearth. 
Make 2 non combustible supports on the left 

and the right side of the burner unit. (see fig. 
1.1) 

 
3.2

 

Chimney breast 

 

The appliance must be built into a non 
combustible existing or a new to be 

constructed false chimney breast. 
For the dimensions of the builders opening 

see fig.1.7. 

framed  

frameless 

A = 670mm 

 

670mm 

B = 

Min. 100mm 

Min. 100mm 

C = 337mm 

 

337mm+wall 

thickness 

D = 

max. 60mm 

wall thickness 

E = 460mm 

 

430mm 

 

Combustible shelf 
F =
 min. 

350mm 

= max.150mm 
If the shelf depth is greater than 150mm, add 

50 mm to shelf clearance height for every 25 
mm increase in shelf depth 

 
For the dimensions of the fire see chapter 11 

till 14. 
 
The false chimney breast must be ventilated 

on top and bottom with a minimum opening 
of 200cm2. 

The false chimney breast and its construction 
may not rest on the appliance. 

Therefore always use a lintel for a brick build 
chimney. 

For the minimum dimensions see fig 1.8. 
 

For the finish, use special stucco (min. 100°C 
resistant) or glass fibre wallpaper to prevent 

discoloration or cracks etc. Recommended 
drying time: for plaster is a minimum of 24 

hours per mm of coat applied. 
 

Содержание Presence

Страница 1: ...Presence Installation Guide and users manual GB IE GB IE 40011221 1138 ...

Страница 2: ...1 UK IRL Installation Guide ...

Страница 3: ...2 UK IRL 1 1 1 2 1 3 1 4 1 5 1 6 ...

Страница 4: ...3 UK IRL 1 7 1 8 2 1 2 2 2 3 2 4 2 5 ...

Страница 5: ...4 UK IRL 2 6 3 1 3 2 3 3 4 1 4 2 A B ...

Страница 6: ...ion The first time the appliance is switched on Let the fire run on maximum setting for several hours so that the lacquer coating will have an opportunity to set and possible vapours released can be safely removed by ventilation We advise you to be outside the room as much as possible during this process Please note that 1 all transport packaging should be removed 2 children or pets should not be ...

Страница 7: ... If necessary convert to framed version Therefore A Remove the build in frame see fig 3 1 B Fit the frame support see fig 3 2 C The frame now can be hung on the support see fig 3 3 4 3 Batteries The battery pack is fixed on a chain inside the burner unit on the right side see fig 2 2 Pull the chain to remove it To avoid overheating take care that the battery pack always is positioned correctly in ...

Страница 8: ...hecking for gas leakage Check all connections and joints for possible gas leaks by means of a gas leak detector or spray 7 3 Checking the burner pressure and the inlet pressure Check whether the burner pressure and the inlet pressure measured agree with the data indicated on the registration plate 7 4 Measuring the inlet pressure Turn off the gas control Get access to the burner unit by removing t...

Страница 9: ...sed and cannot be removed anymore 8 4 Check and cleanup debris To get access to the debris area remove the 1 glass see chapter 5 2 log set 3 burner unit Therefore Remove the bottom plates in the front and at the back see fig 2 3 Unscrew 4 screws 2 at the left and 2 at the right and remove the burner plate including the burner see fig 2 4 Disconnect the gas Unscrew 13 screws of the burner unit and ...

Страница 10: ...7 Gas rate at 15ºC and 1013 mbar l h 542 150 181 Gas rate at 15ºC and 1013 mbar gr h 380 340 Burner pressure at full mark mbar 9 5 20 25 7 Injector main burner mm 2 1 1 3 1 3 Minimum screw mm 1 3 0 85 0 85 Pilot assembly OP9030 OP9222 OP9222 Diameter outlet mm 125mm 5 inch 125mm 5 inch 125mm 5 inch Gas control valve GV60 GV60 GV60 Gas connection 8mm 8mm 8mm Batteries receiver V 4x AA 1 5V 4x AA 1 ...

Страница 11: ...10 UK IRL 11 Dimensions Presence Frameless Top outlet ...

Страница 12: ...11 UK IRL 12 Dimensions Presence Frameless Rear outlet ...

Страница 13: ...12 UK IRL 13 Dimensions Presence Framed Top outlet ...

Страница 14: ...13 UK IRL 14 Dimensions Presence Framed Rear outlet ...

Страница 15: ...14 UK IRL Users manual ...

Страница 16: ...15 UK IRL 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 ...

Страница 17: ...16 UK IRL 1 9 2 0 2 1 2 2 2 3 2 4 2 5 ...

Страница 18: ...aterials in the combustion chamber Never change the position of the log set and never add more decorative materials or carrara pebbles than have been supplied with the appliance If the fire is switched on the pilot light should always be visible Don t place any curtains clothes laundry furniture or other inflammable materials in the neighbourhood of the appliance The minimum safe distance is 100 c...

Страница 19: ...2 2 Wait or press the OFF key to terminate this function fig 2 0 19 2 Setting the transmitter code on the remote control unit Press the reset button of the receiver with a pointed object until the second signal is audible Now press the key on the remote control unit fig 2 1 within 20 seconds If a sound signal is audible the transmitter code has been set 19 3 Temperature clock setting standard C 24...

Страница 20: ...of the periods for day and night temperatures is set within 24 hours 21 2 Setting day and night temperatures Move the SET key fig 1 8 step by step to ÏTEMP Now keep the SET key fig 1 8 pushed in for a long time until the temperature indication in the display screen starts to blink In accordance with your wishes increase the Day temperature with the key fig 2 1 or lower it with the key fig 2 2 Pres...

Страница 21: ... or wait for ten seconds 22 Checkpoints in case of Malfunction If the remote control unit of the fire does not function properly check the following points first 1 Is the toggle switch fig 1 1 set to position I 2 Check the battery chapter 18 5 3 Check whether the receiver responds to the remote control unit If necessary reset the receiver Therefore Briefly pull the battery pack out and remove the ...

Страница 22: ...21 UK IRL ...

Страница 23: ...22 UK IRL ...

Страница 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: