background image

15

TROUBLESHOOTING GUIDE

PROBLEM

CAUSE

SOLUTION

General

Circuit breaker trips or fuse blows 

when unit is turned on

Short in unit wiring.

Trace wiring in unit.

Improper circuit current rating

Additional appliances may exceed the current rating 

of the circuit breaker or fuse.  Plug unit into another 

outlet or install unit on a dedicated 15 amp circuit.

Lights dim in room while the unit 

is on

Unit is drawing close to circuit current 

rating

Move the unit to another outlet or install unit on a 

dedicated 15 amp circuit

Appearance

Fireplace does not turn on with the 

capacative controls

Improper operation

Refer to Operation Section

No incoming voltage from the electrical 

wall socket

Check Fuse/Breaker Panel

Loose wiring

Check wiring connections

Defective capacative control assembly

Replace the capacative control assembly

Defective main control board

Replace the main control board

Fireplace does not turn on with the 

Remote Control

Improper operation

Refer to Operation Section

The batteries in the remote control are 

dead.

Install new battery into the remote control.

Defective remote control

Replace the remote control

Defective capacative control assembly

Replace the capacative control assembly

Defective main control board

Replace the main control board

Flame Frozen

Loose wiring

Check wiring connections

Defective Flicker Motor

Replace Flicker Motor

Defective main control board

Replace the main control board

Flame is not visible

Loose wiring

Check wiring connections

Flame LED light assembly is not working

Replace flame LED light assembly

Relay board is defective

Replace relay board

Defective power supply

Replace power supply

Defective LED power distributor 

(

NIGHT19

 & 

NIGHT25 

only)

Replace LED power distributor

Defective main control board

Replace the main control board

Flame Shudder

Defective Flicker Motor

Replace Flicker Motor

Media bed does not light up

Loose wiring

Check wiring connections

Media LED light assembly is not working

Replace media LED light assembly

Defective main control board

Replace the main control board

Media bed lighting comes on by 

itself

Defective main control board

Replace the main control board

Содержание NIGHT 13

Страница 1: ...T25 6909700100 IMPORTANT SAFETY INFORMATION Always read this manual first before attempting to service this fireplace For your safety always comply with all warnings and safety instructions contained...

Страница 2: ...ENTS Operation Additional key Combinations Maintenance Exploded Parts Diagram NIGHT 13 Exploded Parts Diagram NIGHT 19 Exploded Parts Diagram NIGHT 25 Wiring DiagramS Preparation for Service Main Cont...

Страница 3: ...e corresponding button on the remote when the heater is on Indicated by the Display and a reduced fan speed G Heat Boost Turns the Heater Boost On and Off Runs the unit at the full rated wattage OPERA...

Страница 4: ...e second digit on the Display changing to show H high and L low J Sleep Timer The Sleep Timer can be set to automatically shut off the fireplace after a preset time from 30 minutes to 8 hours To set t...

Страница 5: ...factory dur ing the assembly operation During shipment installation handling etc the partially reflective glass may collect dust particles these can be removed by dusting lightly with a clean dry clot...

Страница 6: ...90100RP 8 Front Glass 5902900100RP 9 Flicker Motor 2000500900RP 10 Flicker Assembly 5902920100RP 11 6 Light LED Flame Assembly 3001670100RP 12 8 Light LED Flame Assembly 3001670200RP 13 4 Light RGB LE...

Страница 7: ...cker Motor 2000480200RP 10 Flicker Assembly 5902920200RP 11 6 Light LED Flame Assembly 3001670100RP 12 8 Light LED Flame Assembly 2 3001670200RP 13 Media Tray 5902910200RP 14 6 Light Coloured Media LE...

Страница 8: ...icker Motor 2000480200RP 10 Flicker Assembly 5902920300RP 11 6 Light LED Flame Assembly 5 3001670100RP 12 Media Tray 5902910300RP 13 6 Light Coloured Media LEDAssembly 5 3001570100RP 14 8 Light Colour...

Страница 9: ...LED ASSEMBLY MEDIA LED ASSEMBLY POWER ADAPTER FAN FAN CERAMIC ELEMENT FLICKER MOTOR FLAME LED ASSEMBLY MEDIA LED ASSEMBLY MEDIA LED ASSEMBLY POWER ADAPTER FAN FAN CERAMIC ELEMENT POWER ADAPTER RELAY...

Страница 10: ...differ for the NIGHT 19 and NIGHT 25 1 Turn the breaker off at the electrical panel 2 Remove the front glass assembly by removing the 2 screws 1 on the left and 1 on the right side located just insid...

Страница 11: ...as above LED POWER DISTRIBUTOR REPLACEMENT ONLY NIGHT19 25 WARNING Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons CAUTION If u...

Страница 12: ...uctions before proceeding 1 Remove the plastic media tray by removing the 4 screws 2 on the left and 2 on the right of the tray Figure 7 2 Lift the plastic media tray out of the unit 3 Remove the fron...

Страница 13: ...removing the 6 screws 3 on the left and 3 on the right of the tray 4 Remove the upper access cover located on the bottom right hand side by removing the screws securing it to the unit 5 Remove the le...

Страница 14: ...s before proceeding 1 Remove the 10 screws that secure the heater assem bly retaining bracket to the unit Remove the bracket and set aside 2 Locate and remove the 4 screws that secure the as sembly to...

Страница 15: ...n Section The batteries in the remote control are dead Install new battery into the remote control Defective remote control Replace the remote control Defective capacative control assembly Replace the...

Страница 16: ...heater is burning off any dust accumulated dur ing manufacturing or operation Defective Heating Element Replace Heating Element Heater fan turns On but heater lacks heat Improper operation Refer to Op...

Отзывы: