Installation manual MatriX 800-1050x500 RD,ST H
11 <
<
<
<
The distance to combustible materials
must be min. 50mm, calculated from the
outside of the flue pipe.
Never start immediately with an
adjustable flue pipe on the appliance.
Horizontal sections should be installed to
allow a slope towards the appliance
(3 degrees).
Built the system from the appliance. If this
is not possible you can make use of an
adjustable flue pipe.
For fitting of the flue system, the 0,5m
length-adjustable pipe must be used.
Make sure that the inner pipe is always
15mm longer than the outer pipe. Wall-
and roof terminal can also be cut. These
components must be secured with a self-
tapping screw.
4.9
Constructing the false chimney
Before positioning the false chimney, we advise to
perform a functional test with the fireplace as
defined in chapter 7 “Checking the installation”.
False chimney
Construct the false chimney of non-
combustible material in combination with
metal profiles or of masonry/concrete
blocks.
Always use a lintel or reinforcing bars
while bricking the false chimney. They
should not be placed directly on the
fireplace.
Make sure that the fireplace never
functions as a load-bearing construction,
because of the expansion of the fireplace
through warmth.
Ventilation
Correct ventilation prevents damaging overheating
of the gas control block and its electronics and also
limits the temperature of the convection air. Use
the (optional) Faber ventilation grids (article
number A9296400) or a similar alternative with a
minimum free passage of 200cm² per grid, in the
space above the fire, when building the false
chimney. Within the false chimney, an horizontal
screen plate, made of non-combustible material,
must be installed just above the ventilation
openings. (see “A” in fig. 1.0 or 1.1).
Installation and finishing
Please note!
Take into account a minimum distance of
2mm due to expansion of the fireplace.
Take into account the thickness of any
finishing layer!
Method I: installation WITH cover strip
For installation and finishing the following points
are of interest (fig. 3.0 a):
G = Build-in frame
H = Spacer profile
Build the false chimney against the build-
in frame G and the spacer profile H
(Fig.3.0b ).
Do not build the false chimney
(underneath the appliance) higher than
the top of the distance profile H.
Method II: installation WITHOUT cover strip (fig.
2.1)
For installation and finishing the following points
are of interest (fig. 3.1a):
I = build-in frame
J = Glass support
K = Upper side of the combustion
chamber setting.
Remove all-round spacer profile H (fig.
3.0b).
Please note!
Ensure that the screws of the spacer profiles H
are replaced to ensure the air tightness of the
device.
For the height of the platform, observe
point K (Fig. 3.1 b).
Due to the expansion of the fireplace,
there should be at least 2mm play
between the platform and the glass
supports J (Fig.3.1 b).
5
Removing glass
5.1
MatriX 800-1050/500 RD
To take out the front glass, the side glass must first
be removed.
Removing the side glass (see fig. 4.0):
Remove trim strip “A”;
Place a suction cup on the glass;
Open both glass clamps at the top;
Move the glass upwards so that the underside
is released from the grooves and pull the glass
downwards.
Remove the front glass
Remove the decorative frames “B” see fig. 4.1;
Place the suction cups on the glass;
Содержание MatriX 800/500 RD H
Страница 2: ...Installation manual MatriX 800 1050x500 RD ST H 1...
Страница 3: ...Installation manual MatriX 800 1050x500 RD ST H 2...
Страница 4: ...Installation manual MatriX 800 1050x500 RD ST H 3 1 0 1 1 1 2 1 3 1 4...
Страница 5: ...Installation manual MatriX 800 1050x500 RD ST H 4 1 5a 1 5b 1 6 1 7 1 8 1 9a 1 9b 1 9c 1 9d 1 9e 1 9f...
Страница 6: ...Installation manual MatriX 800 1050x500 RD ST H 5 2 1a 2 1b 3 0a 3 0b 3 1a 3 1b 4 0 4 1...
Страница 7: ...Installation manual MatriX 800 1050x500 RD ST H 6 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9...
Страница 8: ...Installation manual MatriX 800 1050x500 RD ST H 7 5 0 6 0 6 1...
Страница 19: ...Installation manual MatriX 800 1050x500 RD ST H 18 12 Examples flue materials...
Страница 22: ...Installation manual MatriX 800 1050x500 RD ST H 21 14 Technical data 14 1 MatriX 1050 500 RD H ST H...
Страница 23: ...Installation manual MatriX 800 1050x500 RD ST H 22 14 2 MatriX 1050 500 RD H ST H...
Страница 29: ...Installation manual MatriX 800 1050x500 RD ST H 28 18 2 MatriX 800 500 ST H and MatriX 1050 500 ST H...
Страница 30: ...Installation manual MatriX 800 1050x500 RD ST H 29 18 3 Control box FAB1806...
Страница 31: ...Installation manual MatriX 800 1050x500 RD ST H 30 18 4 Ventilation grid article number A9296400...
Страница 32: ...Installation manual MatriX 800 1050x500 RD ST H 31 18 5 Adjustable feet article number A9319696...
Страница 33: ...Installation manual MatriX 800 1050x500 RD ST H 32...
Страница 34: ...Installation manual MatriX 800 1050x500 RD ST H 33...
Страница 35: ...Installation manual MatriX 800 1050x500 RD ST H 34...
Страница 36: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen...