background image

 

3

1. ASSEMBLY   

 

1.1 Building regulations

  

Your stove is designed for heating of living rooms as supplementary heating or 
for heating during the transitional heating up period. The device is not suitable 
as the unique form of heating for apartments or entire floors. We recommend 
that before installation of your wood stove you talk with your district chimney 
sweep. He can advise you on the relevant building regulations, examine the 
chimney, grant the authorisation and arrange for the approval. Check whether 
the room in which the wood stove is to be installed is adequately supplied with 
fresh air. To ensure trouble-free operation of your stove, an adequate supply of 
combustion air is required from the living room. The stove may not be modified.  

 

1.2 Combustion air supply:  

The arrangements for a combustion air supply may not be modified. In 
particular, it must be ensured that the required combustion air pipes are open 
during operation of the wood stove. 
 
 

  

 
 
 
 
 
 
 
 
For this reason, if you have the intention to seal windows and doors with 
special sealing you should obtain professional advice. Your contact in this case 
is the chimney sweep, plumber, heating engineer or your energy supplier. 
These professionals can tell you what must be done. 
 

1.3 Chimney  

The performance of your wood stove also depends on your chimney. It can be 
affected by the cross-section of the chimney or by an effective chimney height 
of less than 4.50 m. The effective chimney height is the distance between the 
flue gas entry and the upper edge of the chimney. 

Cooker hoods, which are installed in the same room or contiguous air 
area as the wood stove may adversely affect the functioning of the 
wood stove (up to the smoke outlet in the living room despite a closed 
fire box door) and must, therefore, in no case be operated simultane-
ously with the stove.  
In the case of sealed windows and doors (e.g. as part of energy-saving 
measures), it may be that the fresh air supply can no longer be guaran-
teed thus affecting the functioning of your stove. This can negatively 
affect your wellbeing and your safety under certain circumstances. 

Содержание HAAKON

Страница 1: ...Assembly and operating instructions for freestanding wood stove models HAAKON BRANDE 82 April 2007...

Страница 2: ...stove Keep this guide close by to allow you to carry out the correct operations at the beginning of the heating period A guarantee from your dealer or your contractor can only be honoured if the atta...

Страница 3: ...stove For this reason if you have the intention to seal windows and doors with special sealing you should obtain professional advice Your contact in this case is the chimney sweep plumber heating eng...

Страница 4: ...y itself otherwise the smoke draught would be affected We recommend the use of a double wall lining here The chimney should have an easily accessible soot door We recommend that the chimney or the pip...

Страница 5: ...er that most components in the stove flue pipe safety window cladding and controls etc become hot during heating and therefore represent a combustion hazard So please use gloves Children should never...

Страница 6: ...erted 5 If work is being carried out on flammable or explosive materials in the vicinity of the stove the stove must be put out of operation NOTE No liability is accepted for any direct or indirect da...

Страница 7: ...e stove During the combustion process the expansion and contraction of the steel causes slight crackling sounds 3 2 Using the stove in the seasonal transition period During the transitional period spr...

Страница 8: ...with heat resistant paint These heat resistant stove paints do not offer corrosion protection so that rust may occur in unfavorable conditions for example through Wet cleaning near the feet base plate...

Страница 9: ...tion of the stove especially if the stove is heated too strongly The plates need to be checked regularly and may need to be replaced The required plates can be obtained from your dealer as a spare par...

Страница 10: ...h the terms of the carrier For further information on the guarantee please see the information and notes in the respective chapter of these operating instructions IMPORTANT Damage and defects caused b...

Страница 11: ...wards the wood It thus necessary to avoid the ash tray becoming overfull because the ashes may negatively affect the access of the primary combustion air When burning wood logs the slide must first be...

Страница 12: ...r because it can lead to draught problems and exiting of smoke into the living area 5 HEATING WITH Haakon Brande 82 5 1 Initial commissioning Before the first operation of the stove remove any transpo...

Страница 13: ...elighters or wood wool in the centre of the fire area then add 0 5 kg of wood chips in layers The grate should always be covered with wood over its entire surface Ignite firing Place ignition material...

Страница 14: ...sition the damper in the longitudinal direction of the pipe Primary air closed Move primary air slide across to the closed position according to 4 2 Open fire door Slowly so that no smoke enters the l...

Страница 15: ...ide spacing between them and in accordance with the above information at nominal temperatures or light load for the position of the primary air and secondary air slides NOTE On exceeding the maximum a...

Страница 16: ...g Sect 1 3 and 4 4 The wood burns too quickly The chimney draught is too strong Sect 1 3 and 4 4 The wood is cut too small Sect 3 3 and 5 Controls incorrectly set Sect 5 Smoke comes into the living ar...

Страница 17: ...e box width 250 284 mm Weight approx 125 105 kg Space heating capability up to 105 m depending on the thermal insulation of the building Suitable fuels wood logs wood brown coal briquettes Data for ch...

Страница 18: ...18 Dimensions Haakon...

Страница 19: ...19 Dimensions Brande 82...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24 www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501...

Отзывы: