background image

Version 07/11 - Page 9

• This rangehood uses 20 watt halogen lamps.

FOR ALL INSTALLATIONS

1.

Install the grease filters using two hands by first pulling and

turning the knob to the left so that the locking lever does not 
protrude from the filter 

(as in FIGURE 12)

.  Insert the opposite 

end of the filter into the retaining channel.  Insert the knob end 
next, then turn knob to the right to lock the filter into place.

Cleaning

The stainless steel grease filters should be cleaned frequently in 
hot detergent solution or washed in the dishwasher.   Stainless 
steel cleaner should be used on stainless rangehoods. 

 

Abrasives and scouring agents can scratch stainless steel 
finishes and should not be used to clean finished surfaces.

Replacing the Lamps

Before attempting to replace the lamps, make sure that the 
light switch is turned off.  Remove the 2 screws 

(as indicated 

in FIGURE 14)

 that hold the light support and gently pull the 

support down from the hood.  Remove the lamp from the light 
support and replace with new lamp.  Replace the light support 
and fix it into place with the 2 screws. 

An alternative method to replace the lamps is to use a 1 
1/4" suction cup (

FIGURE 15

). Attach the suction cup to 

the bulb and pull firmly down on the bulb and replace with 
a new lamp. 

FIGURE 12

2.

Turn the power supply on.  Turn on blower and lights.  If the

rangehood does not operate, check that the circuit breaker is not 
tripped or the house fuse blown.  If the unit still does not operate, 
disconnect the power supply and check that the wiring connec-
tions have been made properly.

WIRING  DIAGRAM

FIGURE 14

USE  AND  CARE  INFORMATION

This rangehood system is designed to remove smoke, cooking 
vapors and odors from the cooktop area.

For Best Results

Start the rangehood several minutes before cooking to develop proper 
airflow.  Allow the unit to operate for several minutes after cooking is 
complete to clear all smoke and odors from the kitchen.

FIGURE 15

FIGURE 13

Rangehood Control Panel and Hood Operation

The control panel is located on the front edge of the rangehood 
canopy.  The position and function of each control button are 
indicated in 

FIGURE 13

.

CN13

CN9

CN12

CN4

CN7

CN1

FASE

NE
UT
R

O

COM

V1

V2

V3

V4

LU
C.1 F.

LU
C.1 F.

LU
C.1 N

.

LU
C.2 F.

LU
C.2 N

.

LINE IN

120Vac

60Hz ~

L

N

Y-G

W

IRING BOX

Y-G

Faber ATL

1

2

3

4

5

7

6

1

2

3

4

BLU

BL
K

L-B

RED

BL
U

PNK

GRY

BRW

BLK

1

1

BLK

1

2

3

654

7

8

9

123

6

5

4

9

8

7

RED

M8 4V

120V ~

WHT

2

2

WHT

WHT

BR
W

BRW

3

3

BRW

BLU

GRY

4

4

GRY

BLK

BLU

5

5

BLU

ORG

RED

6

6

RED

PNK

7

7

PNK

Y-G

VLT(ORG)

8

8

VLT(ORG)

RED(ORG)

9

9

RED(ORG)

RED

10

10

RED

VLT

11

11

VLT

12

12

TOROID

AL

TRAN

SFORMER

WHT

4

3

BLK

VLT

RED

2

1

BLK

RED

HALOGEN

LAMPS

ORG

2

1

ORG

4

3

RED

VLT

HALOGEN

LAMPS

HALOGEN

LAMPS

ORG
ORG

RED

HALOGEN

LAMPS

VLT

PRI.

SEC.

ELECTRON

IC

TRN

SFORMER

A

B

C

D

Button A.

 Press button to turn fan on / off. Current speed is 

displayed in C display (1, 2, 3)

Button B.

 Press to reduce fan speed to as low as speed 

1, display C shows the speed selected (1, 2, 3). Hold for 3 
seconds to turn on 30 minute delay feature which runs the 
hood for 30 minutes and automatically shuts the hood off. 
Current speed on 30 minute delay is shown in C display with 
a blinking light to indicate 30 minute mode. Shut off the 30 
minute mode by holding down the button for 3 seconds

Button C.

 LED single digit readout display screen

Button D.

 Press button to increase fan speed up to speed 3. 

Hold for 3 seconds to activate intensive speed mode which 
operates hood on highest speed for 10 minutes and then 
returns to previous speed setting. Display C indicates intensive 
speed with an "H" and blinking light. Shut off the intensive 
speed mode by holding down the button for 3 seconds

Button E.

 Press the button to turn on and off lighting. Press 

once to turn the dimmer light on, press twice to turn the normal 
light setting on, and press again to turn off the lighting.

E

Содержание Diamante DIAM36SS

Страница 1: ...nets on both sides of this unit must be a minimum of 18 above the cooking surface or countertop Consult the cooktop or range installation instructions given by the manufacturer before making any cutou...

Страница 2: ...General Ventilating Use Only Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors WARNING TO REDUCE THE RISK OF FIRE ELECTRI CAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Installat...

Страница 3: ...ce qui a trait la combustionainsiqu l vacuationdesgazparlaconduite de chemin e une bonne a ration est n cessaire pour tous les appareils combustion Suivez les conseils et mesuresdes curit dufournisse...

Страница 4: ...Tape PARTS SUPPLIED FOR INSTALLATION 1 Hardware Package 1 Literature Package PARTS NEEDED FOR INSTALLATION 2 Conduit Connectors Power Supply Cable 1 Wall or Roof Cap All Metal Ductwork OPTIONAL ACCES...

Страница 5: ...the 16 1 8 upper chimney that came with the hood Note If 24 or 30 High Backsplash is being installed the distance between the bottom of the hood and the cooktop DISTANCE X IN FIGURE 4A is equal to the...

Страница 6: ...e adjusted for ceilings between 7 11 3 8 and 8 11 1 2 dependingonthedistancebetweenthebottom of the hood and the cooktop distance x Forshorterceilings havethechimneycover s cut at a sheet metal shop F...

Страница 7: ...tall the MOUNTING SCREWS into the wall leaving about 1 4 gap between the wall and the head of the screw 8 For ducted installations determine and make all necessary cuts in the wall for the ductwork In...

Страница 8: ...upply to the White lead of the rangehoodwithatwist ontypewireconnector AttachtheBlacklead of the power supply to the Black lead of the rangehood with a twist on type wire connector Attach the Power Su...

Страница 9: ...ate for several minutes after cooking is complete to clear all smoke and odors from the kitchen FIGURE 15 FIGURE 13 Rangehood Control Panel and Hood Operation Thecontrolpanelislocatedonthefrontedgeoft...

Страница 10: ...sulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or Faber documentation or use of products no...

Страница 11: ...CES N CESSAIRES POUR L INSTALLATION 2 connecteurs de conduit C ble d alimentation 1 capuchon de mur ou de toit Conduit en m tal ACCESSOIRES POUR L INSTALLATION Kit D extension Pour La Chemin e Plafon...

Страница 12: ...la distance entre la hotte et la table de cuisson X en FIGURE 4A Celas accomplitenutilisantplus ou moins du couvercle de la chemin sup rieure Pour plafonds petit coupez les coverclechemin e s Pourplaf...

Страница 13: ...11 1 2 po regardez la distance entre la hotteetlatabledecuisson XenFIGURE4B Celas accomplitenutilisantplusoumoinsdu couvercle de la chemin sup rieure Pour plafonds petit coupez les covercle chemin e...

Страница 14: ...installations avec conduit d terminer et faire toutes les coupes n cessaires dans le mur pour les conduits Installer les conduits avant la hotte 9 D terminer l emplacement appropri pour le c ble d ali...

Страница 15: ...ne et vert sous la vis de mise la terre verte Replacer le couvercle du compartiment de c blage 2 Installer la CHEMIN E SUP RIEURE C de la FIGURE 10 Elargir l g rement les deux bords lat riaux de la ch...

Страница 16: ...e pour enlever la fum e les vapeurs de cuisson et les odeurs de la cuisine Pour de meilleurs r sultats Mettre la hotte en circuit avant de commencer la cuisson Laisser l appareil fonctionner quelques...

Страница 17: ...s d coulant d un accident d une modification de l utilisation incorrecte ou abusive d un incendie d une inondation d un cas de force majeure d une installation inad quate d une installation non confor...

Страница 18: ......

Страница 19: ......

Страница 20: ...991 0427 567_04 170504 D002509_01...

Отзывы: