FIGURE 6
PLAN THE DUCTWORK
First, determine which venting option will be used:
• Horizontal
• Vertical
• Recirculating
FIGURE 7 shows the cabinet cutout dimensions for both 30"
and 36" models. The duct exit will depend upon your specific
installation. For recirculating installations, the duct work must
be extended through the soffit and be covered with a grille.
The charcoal filters and grille are sold as a kit.
PREPARE THE CABINET
1.
Disconnect and move freestanding range from cabinet
opening to provide easier access to upper cabinet and rear
wall. Put a thick, protective covering over cooktops, set-in
ranges or countertops to protect from damage or dirt.
2.
Determine and clearly mark with a pencil the center line
of the cabinet on the wall and on the underside of the cabinet
where the rangehood will be installed.
3.
If the cabinet bottom is recessed, wood filler strips need
to be installed to insure proper alignment with the cabinet bot-
tom. Wood filler strips should be flush or recessed 1/16" to
1/8" within the cabinet bottom as indicated in FIGURE 8.
FIGURE 8
Version 11/98 - Page 5
FIGURE 7
4 3/8"
3 1/4"
2"
3 1/2"
1"
Glass Screen
Extends 7"
9 1/8"
30" Model: 26"
36" Model: 32"
10"
9 1/2"
11"
30" Model: 29 7/8"
36" Model: 35 7/8"
30" Model: 13"
36" Model: 16"
8"
1 5/8"
1 1/4"
2"
2 3/8"