UK/IRL
21
UK/IRL
20
4.4 Placing the log set (continuing)
4.4.1 Model Spectra, Spectra Panorama, Prisma, Cadra and Silva
The logs set consist of a rear log, which is permanently attached
(except for Silva) to the combustion chamber, and four logs. For Silva
place the rear log into the U section in the back of the combustion
chamber.
The logs must rest on the log holder and the rear log.
Ensure that the pilot burner remains visible after installation of the log
set.
When not placing the log set correctly, the flames tend to burn to the
front against the window.
4.3 Fitting the firebox (continuing)
7. Place the log set (see placing log set, chapter 4.4).
8. Before placing the glass; check the glass sealing rope is in good
condition and makes an effective seal. Be sure that there are no
fingerprints on the glass. It is not possible to remove those prints
after you burn the appliance for a while (they are burnt in).
Place the glass in front of the appliance and fix the glass frame or
use the glass clamps.
9. Replace the front and fix it.
4.4 Placing the log set
The logs contain Refractory Ceramic Fibre which when cut or broken
open can be an irritant to skin and the respiratory tract. Always wear
gloves, do not blow dust into air and clean up using a vacuum
cleaner equipped with a HEPA filter.
Never place extra elements of any kind into the combustion chamber.
To guarantee good combustion, the log set may only be installed in
the way specified by Faber International. Any other arrangement can
lead to soot on logs or window. Do not use the fire with broken or
missing logs.
4.4.1 Model Spectra, Spectra Panorama, Prisma, Cadra and Silva
Cadra log-set lay
A = large log
28 x 10 cm
B = medium log
24 x 9 cm
C = small log (wedge)
26 x 8 cm
Spectra, Prisma, Panorama log-set lay
Silva log-set lay