UK/IRL
>
>
>
>
15
0
1
2
3
4
5
6
0
X
X
X
X
X
X
X
0,5
X
0
X
X
X
X
X
1
X
30
0
0
0
0
0
2
40
30
0
0
0
0
0
3
40
40
30
0
0
0
0
4
50
40
40
30
0
0
0
5
50
50
40
40
30
30
0
6
50
50
50
40
40
30
0
7
60
50
50
40
40
40
X
8
60
60
50
50
50
X
X
9
60
60
60
50
X
X
X
10
65
60
60
X
X
X
X
11
65
65
X
X
X
X
X
12
65
X
X
X
X
X
X
4.3.1
Terminal position
Verify if the required terminal position meets the local installation
regulations regarding disturbance, good functioning and ventilation. (Also
see: safety requirements).
Note:
The terminal must be located so that the outlet is not obstructed. If the
flue terminal is located within 2 meters of a footway, path or where
people could come into contact with it, then a suitable terminal guard
must be fitted.
Terminals located close to shared walkways, footpaths etc. could be
subject to legal constraints and this should be pointed out to the
customer before installation. If in any doubt about flue location advice
should be sought from local building control, or if appliance-related, from
the manufacturer including wherever possible a dimensioned sketch.
Avoid locating the terminal in close proximity to plastic materials such as
gutters or other combustibles. If this is unavoidable then a suitable
deflector should be made.
Tabel 4: binnenwerk MV150 (Cadra Nova)
Ve
rtical
le
n
gth
i
n
m
Horizontal length in m
The numbers in the table represent
the width in mm of the flue
restrictor
X
Combination NOT allowed
0
remove flue restrictor
Met opmaa
pt, Cursief
Met opmaa
Engels (Groo