UK/IRL
>
>
>
>
23
Attention:
•
If possible, first install the appliance before building up the false
chimney breast.
•
If possible, install the appliance, before installing the flue. If this is
not possible, a slidable piece of pipe should be used as connection.
5.3
Placing the appliance
Points of attention for placement:
•
If possible, first place the appliance before assembling the flue.
•
If this is not possible then always use an extendible pipe before
connection onto the appliance.
1)
Position the firebox in the fireplace opening. You can adjust the
height with the 4 adjustable feet.
2)
Make the gas connection according to the instructions (also see gas
connection, chapter 5.1).
3)
Assemble the flue system onto the firebox (see chapter 5).
4)
Check, when applicable, if the safety hatch seals the combustion
chamber properly. Do not fasten it at all! If you fasten it, the
explosion safety hatch won’t function properly!
5)
If necessary, place the DC convection system (also consult the
instruction belonging to the DC construction set).
Fig.13: Safety hatch