6.3 Functional balanced flue check
1.
Set the appliance on max. input.
2.
Verify the flame picture, this means no flames against the window, the flame have to
come besides the logs, if not check the log layout.
3.
Check if the flames are yellow after 10 minutes of operation. If you still have a blue
flame or the appliance goes out, check:
-
If the flue pipes are fitted correctly (no leakage);
-
If the wall mounted terminal is placed with the correct side up;
-
If the maximum allowable length of the flue pipe was exeeded;
-
If the appliance has the right set up. Check the ;
-
If the correct flue restrictor is installed.
6.4 Check reference pressure and burner pressure
The appliance is preset to give the correct heat input. No further adjustment is necessary.
Fit a pressure gauge at the burner pressure test point D to check the burner pressure. The
pressure should be checked with the appliance alight and at max.input.The setting pressure
should be as shown at the technical data. After checking the pressure, turn off the
appliance. Remove the pressure gauge and close the sealing screw. Re-light the appliance.
Turn to max. input and test around the test point D for gas soundness using a suitable leak
detection fluid.
Measuring the pressure(voordruk):
1.
Turn off the gas valve on the appliance;
2.
Turn the Inlet pressure test point C (see fig. 22) some and apply the (meetslang);
A. Governor
B. Adjusting
screw
pilot
flame
C. Inlet pressure test point
D. Burner pressure test
point
Содержание BF110V/Straight
Страница 1: ...Natural Fires BF110V Straight and BF120H Relaxed Installation Guide and User Manual 40010550 0441 ...
Страница 2: ...UK IRL 2 ...
Страница 11: ...UK IRL 11 BF110V Straight Frameless Top view false chimney breast Top view of the appliance ...
Страница 12: ...UK IRL 12 Front view false chimney breast BF110V Straight Frameless ...
Страница 13: ...UK IRL 13 BF110V Straight With frame Top View Front View ...
Страница 14: ...UK IRL 14 BF120H Relaxed Frameless Top view Front view Cross section side view Cross section side view detail ...
Страница 15: ...UK IRL 15 Top View Front View Front View Cross section side BF120H Relaxed With frame ...
Страница 16: ...UK IRL 16 Operation door ...
Страница 41: ...UK IRL 41 User guide ...
Страница 42: ...UK IRL 42 ...