UK/IRL
>
>
>
>
17
3.3 Flue requirements
The appliance is of the type C11/C31. The appliance will need to be supplied with the
approved flue pipes and terminal, it is not possible to supply your own.
The minimum effective height of the flue system must be 0.5 or 1 meter, depending on the
appliance.
Flue routing;
-
The terminal locations, through the wall as well as through the roof;
-
A horizontal extension with elbows is allowed for a maximum of 6 meters (depending
on the type and situation);
-
Vertical max. 12 meters.
Determine on the base of the table 2 and 3, depending on the type and terminal position, if
the desired situation is possible. To establish this you will need to calculate:
-
The effective height (this is the real difference in height between the upper side of
the appliance and the terminal);
-
The total horizontal extension. This is the total horizontal flue length where:
o
Each elbow, which is in the horizontal area, counts for 2 meters;
o
Each 45-degree bend, which is in the horizontal area, counts for 1 meter;
o
Elbows and bends at the transition of horizontal to vertically are not to be
counted;
o
The wall mounted terminal counts for 1 meter.
Flue restrictor
If applicable, in the table is also stated the size of a flue restrictor. This restrictor needs
to be fitted in the combustion chamber when placing the appliance (see chapter 4.2).
Normally the smallest flue restrictor is fitted.
Содержание BF110V/Straight
Страница 1: ...Natural Fires BF110V Straight and BF120H Relaxed Installation Guide and User Manual 40010550 0441 ...
Страница 2: ...UK IRL 2 ...
Страница 11: ...UK IRL 11 BF110V Straight Frameless Top view false chimney breast Top view of the appliance ...
Страница 12: ...UK IRL 12 Front view false chimney breast BF110V Straight Frameless ...
Страница 13: ...UK IRL 13 BF110V Straight With frame Top View Front View ...
Страница 14: ...UK IRL 14 BF120H Relaxed Frameless Top view Front view Cross section side view Cross section side view detail ...
Страница 15: ...UK IRL 15 Top View Front View Front View Cross section side BF120H Relaxed With frame ...
Страница 16: ...UK IRL 16 Operation door ...
Страница 41: ...UK IRL 41 User guide ...
Страница 42: ...UK IRL 42 ...