Three Screws

Rangehood Body

Front

Strip

CUSTOMIZING  YOUR  RANGEHOOD

The front strip of the rangehood can be customized. The 

front strip is attached to the rangehood by three recessed 

screws and three key hole slots on the back side of the strip 

as indicated in 

FIGURE 15

.  It is necessary only to remove 

the three lower screws to remove the front strip.  The top 

screws will slide out of the key holes once the three lower 

screws are removed.

Side View of the Rangehood

The front strip dimensions are given in 

FIGURE 16

. If you 

wish to keep the frame of the front panel and only replace the 

glass panel, the dimensions follow: Height = 5 11/16", Depth 

= 1/8", Width = 29 11/16" (for 30" model) 35 11/16" (for 36" 

model) 23 5/8" (for 24" model).

FIGURE  16

WIRING  DIAGRAM

• This rangehood uses Flourescent Lamp Type 18", 15W T8 and 

Starter Type S2.

Rangehood Control Panel

All controls are located under the front panel and are shown in 

FIGURE 17

.

Light On/Off Switch  ( L )

On/Off switch for the fluorescent light.    Moving the switch to the 

1 Position turns the light On.  Moving the switch to the 0 Position 

turns the light Off.

FIGURE  15

FIGURE  17

FIGURE  18

Blower Speed Switch   ( S )

Controls blower speed.  Moving the switch to the 1 Position turns 

the blower on LOW.   Moving the switch to the 2 Position turns the 

blower on MEDIUM.  Moving the switch to the 3 Position turns the 

blower on HIGH.

Operation Indicator Light  ( I )

Red light will be on when the rangehood is operating.

Microswitch  ( MS )

When the front panel of the rangehood is closed, the rangehood 

will turn off by a microswitch.  This turns the rangehood On and 

Off without adjusting the switches for the Light or Blower and it 

remembers the last speed setting.

Cleaning

The metal grease filters should be cleaned frequently in hot deter

-

gent solution or placed in the dishwasher.   Clean exterior surfaces 

with hot soapy water.  Using abrasives and scouring agents can 

scratch rangehood finishes and should not be used to clean finished 

surfaces.

Replacing the Fluorescent Light

To replace the fluorescent light, remove the retainer clips from both 

ends of the glass diffuser as indicated in 

FIGURE 18

.  Carefully 

slide the glass diffuser all the way to the left.  Lower the right end 

of the glass below the support flange, then remove the glass by 

sliding it back to the left.  Replace the diffuser glass by reversing 

these directions.

23 5/8"  or  29 15/16"  or  35 15/16"

5 7/8"

13/16"

USE  AND  CARE  INFORMATION

This rangehood system is designed to remove smoke, cooking 

vapors and odors from the cooktop area.

For Best Results

Start the rangehood several minutes before cooking to develop proper 

airflow.  Allow the unit to operate for several minutes after cooking 

is complete to clear all smoke and odors from the kitchen.

Blower On/Off 

Switch  ( M )

On/Off switch for the 

blower.    Moving the 

switch to the 1 Posi-

tion turns the blower 

On.  Moving the switch 

to the 0 Position turns 

the blower Off.

Содержание AGIO

Страница 1: ... sans surveillance à la puissance de chauffage maximale un renversement débordement de matière graisseuse pourrait provoquer une inflammation et le génération de fumée Utiliser toujours une puissance de chauffage moyenne ou basse pour le chauffage d huile b Veiller à toujours faire fonctionner le ventilateur de la hotte lors d une cuisson avec une puissance de chauffage élevée ou lors de la cuisso...

Страница 2: ...ical connection cut a 1 1 4 hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TOREDUCETHERISKOFFIREORELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRI CAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufactu...

Страница 3: ...un rendement maximal en ce qui a trait à la combustionainsiqu àl évacuationdesgazparlaconduite de cheminée une bonne aération est nécessaire pour tous les appareils à combustion Suivez les conseils et mesuresdesécuritédufournisseurtelsqueceuxpubliés par l Association Nationale de la Sauvegarde contre l Incendie et l Association Américaine d Ingénieurs de Chauffage Frigorifaction et Air Climatisé a...

Страница 4: ...ucted with the required minimum of 3 1 4 by 10 rectangular duct Calculate the length of the ductwork by adding the equivalent feet in FIGURE 4 foreachpieceofductinthesystem AnexampleisgiveninFIGURE 5 For best results use no more than three 90 elbows Make sure that there is a minimum of 24 of straight duct between elbows if more than one is used Do not install two elbows together If you must elbow ...

Страница 5: ...crewdriver remove the backdraft damper by loosening the screw marked with a red dot on top of the rangehood 3 Before installing the rangehood must be adjusted for venting For ductless installations read the following section which discusses special requirements for these installations before continuing For Horizontal or Vertical ducting the respective exhaust knockout must be removed Each knockout...

Страница 6: ...operation 5 Attach the cover behind the exhaust grate with two silver screws supplied with the rangehood as indicated in FIGURE 12 11 Replace the field wiring compartment cover For duct less installations refer to the next section which discusses ductless installations Replace the grease filters 12 Turn the power supply on Turn on blower and light IF THE RANGEHOOD DOES NOT OPERATE Check that the c...

Страница 7: ...n turns the blower on HIGH Operation Indicator Light I Red light will be on when the rangehood is operating Microswitch MS When the front panel of the rangehood is closed the rangehood will turn off by a microswitch This turns the rangehood On and Off without adjusting the switches for the Light or Blower and it remembers the last speed setting Cleaning The metal grease filters should be cleaned f...

Страница 8: ...umbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than normal single family household use 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes o...

Страница 9: ... horizontal pour cette hotte La figure 3 montre l ouverture d échappement pour l installation sans conduit calcul de longueur du conduit La longueur du conduit ne doit jamais excéder 25 pi s il s agit de conduit rectangulaire de 3 1 4 po Calculer la longueur du conduit en ajoutant l équivalent en pied de la FIGURE 4 pour chaque pièce du conduit du système Un exemple est donné à la FIGURE 5 Pour de...

Страница 10: ...a hotte 1 Retirer l appareil de la boîte et le déposer sur une surface plate pour l assemblage Couvrir la surface pour éviter tout dommage accidentel Retirer toutes les pièces incluant 1 registre à clapet les vis et le nécessaire d instructions avant de jeter la boîte 2 Retirer les deux filtres pour la graisse de l appareil et les mettre de côté La hotte est expédiée de l usine avec un registre de...

Страница 11: ... Mettre en circuit le ven tilateur et la lumière Si la hotte ne fonctionne pas Vérifier si le disjoncteur n est pas hors tension ou si un fusible n est pas grillé Débrancher l alimentation et vérifier si les connexions ont été faites de façon adéquate installations sans conduit Les installations sans conduit requièrent le nécessaire sans conduit Le ventilateur doit être placé de façon à ce que l é...

Страница 12: ...rcuit ON et hors circuit OFF sans ajustement des interrupteurs de la lumière ou du ventilateur et la hotte se rappellera du dernier réglage de vitesse Nettoyage Les filtres à graisse en métal devraient être nettoyés fré quemment dans une solution d eau chaude et de détergent ou mettre au lave vaisselle Nettoyer les surfaces extérieu res à l eau chaude savonneuse Ne pas utiliser de produits abrasif...

Страница 13: ... maison ou pour corriger votre câblage ou votre système de plomberie 2 Les appels de service pour remplacer ou réparer les ampoules les fusibles ou les filtres de votre hotte de cuisinière 3 Les réparations lorsque votre hotte de cuisinière a été utilisée plus que la normale c est à dire plus que pour une famille par foyer 4 Les dommages résultant d un accident de l altération d une mal utilisatio...

Отзывы: