Parameter P30: Limit for hysteresis T1 downwards
Parameter P31: Limit for hysteresis T1 upwards
Parameter P32: Limit for hysteresis T2 downwards
Parameter P33: Limit for hysteresis T2 upwards
Setting of input limits for hysteresis at programming level.
Range: 0 .. 99 K
Parameter P70: Minimum action time for compressor K1
Setting of minimum action time for compressor relay contacts K1,
in order to prevent repeated switching on and off.
Range: 0.0 .. 999 seconds.
Parameter P71: Minimum pause time for compressor K1
Setting of minimum pause time for compressor relay contacts K1,
in order to prevent repeated switching on and off.
Range: 0.0 .. 999 seconds.
Parameter P80: Switch from target temperatur T1 to T2
Setting of funktion: "switching target temperature"
0 = not possible
1 = with button
2 = do not use.
Parameter P81: Function intermittend stirring
Setting of funktion: "start manual intermittend stirring".
See section "Intermediate stirring options during cooling" - page
14.
0 = not possible
1 = Standard (activate intermittend stirring "short" or "long" with
button)
2 = do not use.
3 = permanent stirring ON / OFFPress button "Agitator" to start
permanent stirring, press button "Agitator" again to stop the
stirrer.
Parameter P99: temperature scale
0 = Celsius
1 = not posible