MOUNTING THE PROFILE

POSITIONING THE MODULES

WIRING

GREEN

BROWN

YELLOW

WHITE

BLACK

PINK

GREY

VIOLET

RED**

BLUE**

POWER SUPPLY

STOP IMPULSE
OPENING SIDE

REVERSE IMPULSE
CLOSING SIDE

TEST OUPTUT***

The transmitter (TX) should be placed 
next to the door edges that need to be 
protected.

The angle adjustment clip should be 
next to the transmitter.

Turn the module if necessary.

When a module needs to be turned:

1. detach the clips
2. turn them by 180°
3. reattach

NO POWER

NO DETECTION

DETECTION

The module connected to the door 
controller becomes the 

MASTER

.

Plug the SLAVE 
CABLE between 
the modules in 
one of the two 
placements. 

Mount the profi les as close as possible 
to the closing edge. 
Leave 2 cm for the black end caps.

Take the position of the white clips 
into account before drilling and 
fastening the screws.

*  Output status when sensor is operational 
**   For compliance with DIN 18650, connection to door controller test output is required.
*** If door controller is not tested: conncect BLUE to 0 V and RED to +12 V - 30 V DC.

4

6

5

4

5

X

SETTINGS

DOOR SAFETY CHECK

CALIBRATION

IMPORTANT

: Test the good 

functioning of the installation 
before leaving the premises.

If necessary, position spots 
closer to or away from the door 
and 

relaunch a calibration

.

After changing a DIP-switch, the orange LED fl ashes. 

A LONG push on the push button of the 

MASTER

 

confi rms the settings of ALL MODULES.

Afterwards, a number of green fl ashes (x) indicates 
the number of connected modules

.

A SHORT push on the button of the 

MASTER

 launches a 

calibration on ALL MODULES.

Do not stand in the detection fi eld!

When the LED is off on all modules, the detection zone is OK.

The detection zone is too short: 
turn the screw clockwise.

The detection zone is too long: 
turn the screw anticlockwise.

Step out of the detection fi eld. 
If necessary, change angle or switch off background (DIP 3 = OFF).

Launch a new calibration. 

The fl ashing speed of the LED 
increases when approaching 
the optimal position.

MOUNTING

 SIDE

FREQUENCY

BACKGROUND

UNCOVERED 

ZONE

RELAY 1

OPENING SIDE

RELAY 2

CLOSING SIDE

FREQ A

FREQ B

ON

OFF

35 cm*

15 cm

ON

OFF

LED during detection:
R1 > RED
R2 > GREEN

Set different 
frequencies on 
modules close to 
each other.

Not enough background 
refl ectivity: switch to OFF

Mounting height > 2.7 m: 
switch to ON to allow for
DIN 18650-conformity

Approximate values 
at 1.8 m.

* Recommended for 
most applications

RED-GREEN

OFF

GREEN

RED

ORANGE

ORANGE

GREEN

OFF

FACTORY VALUE