3 MEMORY-STORING THE ANEMOMETER ON THE MOTOR
WITHIN 5 SECONDS
WITHIN 5 SECONDS
2 SECONDS
Fig.11
PLACE THE RUBBER CABLE GLAND
CORRECTLY
PRESS BOTH TEST PUSH-BUTTONS
WITHIN 10
SECONDS
1) Supply power to the motor.
2) On an already memory-stored remote control press, within 10 seconds, the programming push-button for 2
seconds.
3) Within 5 seconds press the STOP/PREFERRED POSITION push-button on the same remote control
4) Within 5 seconds, simultaneously press both test push-buttons on the anemometer to be added. (The anemometer
shall be supplied with power)
5) The motor performs two brief movements in both directions to confirm the memory storage.
6) Press one of the two TEST push-buttons to check the up movement of the rolling shutter (to carry out the TEST, the
limit switches must be set)