4
4
5
230 V ~
N
L
e
f
h
i
g
j
ENGLISH
2.2 ALTERNATIVE FASTENING OPERATION
1) According to figure 8 ref.
a
, remove the covers and unscrew the fastening screws.
2) Turn upward the part
b
in figure 8, keeping the four cover closing screws directed to the sun sensor.
3) Join both parts of the anemometer, select the desired angle and fit the two fastening screws but do not tighten
them (Fig. 9 ref.
c
).
4) Remove the protective cover (Fig.9 ref.
e
).
5) Move the anemometer cable in order to have the three securing holes free (Fig. 10 ref.
f
)
6) Drill the securing holes for the anemometer on the wall in correspondence with its holes. (Fig. 10 ref.
g
)
7) Secure the anemometer to the wall using the relevant screws and/or dowels.
8) Place the anemometer cable in its seat
9) Drill the cable bushing correctly, lead the power cable to the terminals of the anemometer passing through this
hole (Fig. 11 ref.
h
)
10) Be careful when positioning the rubber cable gland in its seat. (Fig. 11 ref.
i
)
11) Fit the cable tie supplied
12) Turn the anemometer until reaching the desired angle
13) Tighten both side fastening screws and fit the covers
Fig.6
Fig.7
PLACE THE RUBBER CABLE
GLAND CORRECTLY
Содержание TM XA R 433
Страница 1: ...TM XA R 433...
Страница 6: ...a a b d c c e f g ENGLISH Fig 8 Fig 9 Fig 10...