![FAAC R180 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/faac/r180/r180_manual_3137447008.webp)
MASTER
SLAVE
NEUTRAL
=
=
=
ENGLISH
8
8 CONNECTION OF TWO R180/280 UNITS
For shutters with a width of over 4.5 meters, we advise installing two R180
or R280 operators at the sides of the shutter as shown in Fig. 20.
Fig. 21
Fig. 20
Perform the installation procedures of both drive units as explained in
chapter 3. At the end of the mechanical installation, refer to the following
procedure:
Remove the service bracket, ref.
fig. 11, from both drive units,
and keep it;
When the service bracket has been removed, take
great care NOT TO MOVE the transmission crowns
of the operators in order not to compromise the
positioning of the screws of the travel-limit devices.
Open the cover of both travel-limit units;
Remove the power cable of the SLAVE drive unit and make the
connections as indicated in figure 21;
Close the cover of both travel-limit units and reposition the service
brackets.
Continue the installation performing, only for the MASTER operator, the
instructions given from chapter 5 on page 6.
Therefore the travel-limit devices will be adjusted only on the MASTER unit
as described in chapters 6 and 6.1.
The electro-brake can be installed independently on the MASTER or
SLAVE unit.
1.
2.
3.
4.
Assemble the release knob in Figure 18, taking care to fully fasten
the regulator in ref.
;
Pull the cable and firmly tighten terminal ref.
:
- To release the gearmotor, restrain the top of the knob and
rotate the bottom part clockwise;
- To relock the gearmotor, restrain the top of the knob and rotate
the bottom part anti-clockwise;
5.
6.
Remove the cover of the travel limit unit, unfastening the three
visible screws;
Connect the two eyelets coming from the electro-brake to the
terminal-board of the travel limit unit, as shown in Fig.19 ref.
and
;
Close the cover of the travel limit unit.
7.
8.
9.
Fig. 19
Fig. 18