manualshive.com logo in svg
background image

ENGLISH

2

CE DECLARATION OF CONFORMITY FOR MACHINES

(DIRECTIVE 98/37/EC)

Manufacturer: FAAC 

S.p.A.

Address: 

Via Benini, 1  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that:  Operator model  R180, R280,

 

•  is built to be integrated into a machine or to be assembled with other machinery to create a machine under the 
provisions of Directive 98/37/EC;

 

•  conforms to the essential safety requirements of the following EEC directives:

 

  73/23/EEC and subsequent amendment 93/68/EEC.

 

   89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC

 

  and also declares that it is prohibited to put into service the machinery until the machine in which it will be integrated 
or of which it will become a component has been identified and declared as conforming to the conditions of 
Directive 98/37/EC.

 

Bologna, 28 February 2007

 

 

    The 

Managing 

Director

  

A. 

Bassi

 

1)  ATTENTION! To ensure the safety of people, it is important that you read 

all the following instructions. Incorrect installation or incorrect use of the 

product could cause serious harm to people.

  2)  Carefully read the instructions before beginning to install the product.
  3)  Do not leave packing materials (plastic, polystyrene, etc.) within reach 

of children as such materials are potential sources of danger.

  4)  Store these instructions for future reference.
  5)  This product was designed and built strictly for the use indicated in this 

documentation. Any other use, not expressly indicated here, could 

compromise the good condition/operation of the product and/or be 

a source of danger.

  6)  FAAC declines all liability caused by improper use or use other than that 

for which the automated system was intended.

  7)  Do not install the equipment in an explosive atmosphere: the presence 

of inflammable gas or fumes is a serious danger to safety.

  8)  The mechanical parts must conform to the provisions of Standards 

EN 12604 and EN 12605.

    For non-EU countries, to obtain an adequate level of safety, the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

  9)  FAAC is not responsible for failure to observe Good Technique in 

the construction of the closing elements to be motorised, or for any 

deformation that may occur during use.

 10)  The installation must conform to Standards EN 12453 and EN 12445.
    For non-EU countries, to obtain an adequate level of safety, the 

Standards mentioned above must be observed, in addition to national 

legal regulations. 

 11)  Before attempting any job on the system, cut out electrical power.
 12)  The mains power supply of the automated system must be fitted with 

an all-pole switch with contact opening distance of 3mm or greater. 

Use of a 6A thermal breaker with all-pole circuit break is 

recommended.

 13)  Make sure that a differential switch with threshold of 0.03 A is fitted 

upstream of the system.

 14)  Make sure that the earthing system is perfectly constructed, and connect 

metal parts of the means of the closure to it. 

 15)  The automated system is supplied with an intrinsic anti-crushing safety 

device consisting of a torque control. Nevertheless, its tripping threshold 

must be checked as specified in the Standards indicated at point 10.

 16)  The safety devices (EN 12978 standard) protect any danger areas 

against 

mechanical movement Risks

, such as crushing, dragging, and 

shearing.

 17)  Use of at least one indicator-light (e.g. FAACLIGHT) is recommended 

for every system, as well as a warning sign adequately secured to the 

frame structure, in addition to the devices mentioned at point “16”.

 18)  FAAC declines all liability as concerns safety and efficient operation of 

the automated system, if system components not produced by FAAC 

are used.

 19)  For maintenance, strictly use original parts by FAAC.
 20)  Do not in any way modify the components of the automated 

system.

 21)  The installer shall supply all information concerning manual operation 

of the system in case of an emergency, and shall hand over to the user 

the warnings handbook supplied with the product.

 22)  Do not allow children or adults to stay near the product while it is 

operating.

 23)  Keep radiocontrols or other pulse generators away from children, to 

prevent the automated system from being activated involuntarily.

 24)  Transit is permitted only when the automated system is idle.
 25)  The user must not attempt any kind of repair or direct action whatever 

and contact qualified personnel only.

 26)  Maintenance: check at least every 6 months the efficiency of the 

system, particularly the efficiency of the safety devices (including, where 

foreseen, the operator thrust force) and of the release devices.

 27)  Anything not expressly specified in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

Содержание R180

Страница 1: ...UTOMATED SYSTEM 4 3 1 PRELIMINARY CHECKS 4 3 2 INSTALLATION DIMENSIONS 4 3 3 INSTALLING THE OPERATOR 4 4 TRAVEL LIMIT UNIT 6 5 ELECTRICAL CONNECTIONS 6 5 1 BUTTON BOARD OR SELECTOR 230 Vac 6 5 2 COMMA...

Страница 2: ...ds EN 12453 and EN 12445 For non EU countries to obtain an adequate level of safety the Standards mentioned above must be observed in addition to national legal regulations 11 Before attempting any jo...

Страница 3: ...nt temperature 40 C 55 C Shutter Shaft Diameter 60 48 42 mm 60 48 42 mm Winding Flange Diameter 200 220 mm 200 220 mm Maximum Shutter Height 8 m 8 m Maximum Shutter Width 4 5 m 4 5 m Operator Weight 8...

Страница 4: ...he shutter shaft removing deposits of dust grease and chips To install two R180 or R280 operators on a shutter having a width of over 4 5 meters please refer to chapter 8 on page 8 Procedure for defin...

Страница 5: ...on the winding shaft Insert in the hole you have just drilled the securing screw in Fig 7 ref tightening it to rest on the washer and self locking nut 5 6 If in chapter 1 2 you have measured a windin...

Страница 6: ...power supplied by a 230 VAC selector or by control boards 200 BT and 200 MPS To install two R180 280 units on the same winding shaft please refer to chapter 8 on page 8 BEFORE performing the followin...

Страница 7: ...ake the shutter into its fully closed position to obtain full access to the travel limit unit 1 As shown in Figure 14 incline downward and keep inclined the rotation constraint lever ref to enable rel...

Страница 8: ...1 Close the cover of both travel limit units and reposition the service brackets Continue the installation performing only for the MASTER operator the instructions given from chapter 5 on page 6 There...

Отзывы: