5.4 TROUBLESHOOTING
Below are a series of tips to help identify and solve a number of
particular issues.
3
Troubleshooting
CONDITION
SUGGESTION
The bollard raises by a few centime-
tres and then lowers immediately
Make sure that you have selected default No.
5 on the JE275 board (§ 5.2)
Make sure that the DL3 (FSW) LED on the
JE275 board remains on for the entire move-
ment.
Make sure that the pressure switch (if present)
has been wired correctly.
Replace the pressure switch (if present)
The bollard reaches the high position
and reverses immediately.
Make sure that the limit switches are wired
correctly.
25
Make sure that the upper limit switch is in the
correct position
2
-
7
The bollard does not raise.
Make sure that you have selected default No.
5 on the JE275 board (§ 5.2)
Make sure that the bollard is set for automatic
operation (§ 4.6)
Check the wiring of the motor
The bollard will not lower, and
remains in the high closed position.
Check that there is nothing between the cyl-
inder and the slide bushing that is preventing
movement
Check the wiring of the motor
The flashing LED light is not working
Make sure that you have selected default No.
5 on the JE275 board (§3.2)
Make sure that the power supply connector
located under the head is plugged in correctly.
Check the accessories fuse on the JE275 board.