The gate operator may utilize PLD1500 Plug-in Loop Detectors to simplify installation, save space and eliminate extra wiring.
There are three plug-in terminals (Shadow, Reverse, Open) located on the gate controller. Detectors plugged into a specific
socket will perform that function. To connect a PLD1500:
E
XTERNAL
L
OOP
D
ETECTOR
C
ONNECTIONS
:
The gate operator may utilize external Loop Detectors. Refer to the manufacturer’s instructions for detailed wiring.
Plug-In Loop Detector Inputs:
1. Shadow Loop: Not used on FSL700.
2. Reverse Loop: Plug detector into center socket. Make
sure detector is secure and snapped in.
3. Open Loop: Plug detector into left socket. Make sure
detector is secure and snapped in.
4. Set different frequencies for each loop detector.
5. Follow the directions provided with the PLD1500 for
more detailed settings.
Ground Loop Wire Connections:
1. Connect Reverse Loops wires to REVERSE 1 and 2. For
fail safe operation connect reverse loops in series.
2.
Connect Open Loop wires to OPEN 1 and OPEN 2.
Vehicular Gate Only
R
EVERSE
L
OOP
R
EVERSE
L
OOP
O
PEN
L
OOP
4-5 Feet
4-5 Feet
External Loop Detector Inputs:
1. 24VDC is available to power external loop detectors.
Connect 24VDC detector power to +24VDC and
COMMON.
2. Shadow Loop: Not used on FSL700.
3. Reverse Loop: Connect relay wires to REVERSE N.O.
and COMMON.
4. Open Loop: Connect relay wires to OPEN N.O. and
COMMON.
5. Set different frequencies for each loop detector.
6. Follow the directions provided by the external loop
detector manufacturer for more detailed settings.
FSL700 Slide Gate Operator