The gate operator is equipped with an inherent (Type A) entrapment sensing system.  The sensor detects obstructions in both 
the open and close path of the gate.  There is an OPEN SENSITIVITY Adjustment and a CLOSE SENSITIVITY Adjustment.  
To adjust the sensitivity: 

1.  Activate the gate to open. 

2.  While the gate is running open, slowly rotate the OPEN SENSITIVITY adjustment clockwise to INCREASE the 

sensitivity until the gate stops in mid-travel. 

3.  Gently rotate the OPEN SENSITIVITY adjustment counter-clockwise 1/8 turn to DECREASE the sensitivity. 

4.  Activate the gate to close. 

5.  While the gate is running closed, slowly rotate the CLOSE SENSITIVITY adjustment clockwise to INCREASE the 

sensitivity until the gate stops in mid-travel. 

6.  Gently rotate the CLOSE SENSITIVITY adjustment counter-clockwise 1/8 turn to DECREASE the sensitivity. 

7.  Operate the gate a few times to be sure it fully cycles without stopping. 

8.  Place an immobile object in the open path of the gate to stop the gate while in travel.  The gate should stop and enter 

a Soft Shutdown upon striking the object. 

9.  Place an immobile object in the closed path of the gate to stop the gate while in travel.  The gate should stop and 

enter a Soft Shutdown upon striking the object. 

10. Repeat steps 2 - 6 until the correct sensitivity adjustment is found. 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 
 

R

EVERSE

 S

ENSITIVITY

 S

HUTDOWN

Upon a first obstruction, the reverse sensor should: 

1.  Stop the gate and reverse it approximately two (2) inches. 

2.  Disable the Timer To Close Feature until the gate operator receives a new command = Soft Shutdown. 

3.  Any standard input can reactivate the gate and return it to normal operation. 

 
Upon a second consecutive obstruction before the gate reaches either limit, the reverse sensor should: 

1.  Stop the gate. 

2.  Disable the gate operator = Hard Shut Down. 

3.  Sound the audio alarm for five (5) minutes or until the operator has been reset. 

4.  Only resetting the operator will reactivate the gate and return it to normal operation. 

5.  To reset the operator in a Hard Shut Down situation:  Press the reset button on the left side of the controller or turn 

the power switch OFF and back ON. 

 

 

For the Reverse Sensor to function correctly, the gate must be properly installed and work freely in both directions.  

Repair or replace worn hardware.  DO NOT use sensitivity to compensate for a gate in need of service. 

Clockwise Turn: 
     INCREASE

 Sensitivity 

       (Reverse the gate more easily) 

Counter-Clockwise Turn: 
     DECREASE

 Sensitivity 

       

(Reverse the gate less easily)

 

Gently rotate each 

adjustment.  Turning 

the adjustment POT 

too hard will break the 

adjustment. 

CAUTION: 

FSL700 Slide Gate Operator 

18 

Содержание FSL700

Страница 1: ...nal Inc Headquarter East Coast Operations 5151 Sunbeam Road Suites 9 11 Jacksonville FL 32257 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Unit...

Страница 2: ...Reverse Sensitivity Shutdown 18 Close Time Delay Adjustment 19 DIP Switch Settings 19 ACCESSORY CONNECTIONS Accessory Wire Overview 20 Edge Sensor Connections 21 Photo Sensor Connections 22 Standard R...

Страница 3: ...nderstand the manufacturer can not be held responsible for damage or injury caused by improper erroneous or unreasonable use Failure to comply with these guidelines may create a dangerous situation an...

Страница 4: ...clear line of sight with the gate and its travel Activating devices must be installed a minimum of 10 feet away from the gate Be sure to mount ALL operating devices clearly out of reach of through gat...

Страница 5: ...ntact sensors generally are photoelectric cells or like devices For gate operators utilizing non contact sensors 1 Refer to the diagram below for placement of non contact sensors 2 Use care to reduce...

Страница 6: ...lding structures landscaping or similar obstructions All wireless contact sensors shall function under the intended end use conditions MANUAL RELEASE To manually release the gate operator remove the c...

Страница 7: ...barrier such as a swinging sliding raising lowering or the like barrier that is a stand alone passage barrier or is that portion of a wall or fence system that controls entrance and or egress by peop...

Страница 8: ...or replace worn or damaged gate hardware before installing the gate operator Add safety devices such as warning signs photo eyes and reverse edges to help prevent injuries or death Reduce all pinch po...

Страница 9: ...Horse Power 1 2 HP 500 Watt Power Input 120 VAC Current 6A Cycles Hour 75 Travel Speed Approx 12 inches sec Maximum Gate Weight 1000 lbs Maximum Gate Length 40 Feet Primary Entrapment Protection Inhe...

Страница 10: ...Disadvantages Twice as much chain is required for this type of application added expense The application requires the use of an additional idler sprocket added expense FRONT MOUNT METHOD The front mou...

Страница 11: ...ed bring all conduits up to one side and terminate in a Bell Box Make connections to the operator using water tight flex conduit 6 Form the concrete pad as shown and pour concrete Allow the concrete t...

Страница 12: ...with each other Tighten the anchor bolts to securely hold the operator CHAIN CONNECTION FRONT MOUNT Once the gate operator is securely bolted down the chain may be attached To attach the chain for a f...

Страница 13: ...t so the chain from the lower chain idler is level with the bottom of the endless idler Approximately 11 Make sure the chain will be in a straight line and same height as the lower idler sprocket 5 We...

Страница 14: ...ll the bottom limit nut until it activates the bottom limit switch The switch will click when activated 4 Release the limit guide plate and make sure it is engaged in the slots of each limit nut 5 Rea...

Страница 15: ...power should be supplied from a circuit breaker panel and must have its own dedicated circuit breaker This supply must include a green ground conductor 3 Only use U L approved 14 AWG or larger 600 Vol...

Страница 16: ...r DO NOT USE THESE POWER OUTLETS FOR INSTALLATION OR SERVICE TOOLS Each plug supplies 110 VAC when AC power is active to the gate operator If AC is not available the power plugs will not supply power...

Страница 17: ...nit If one gate travels further than the other the gate that travels further must be the Master 2 Turn Slave Operator DIP Switch 3 to ON SLAVE 3 Turn Master Operator DIP Switch 3 to OFF MASTER 4 WIRED...

Страница 18: ...in travel The gate should stop and enter a Soft Shutdown upon striking the object 10 Repeat steps 2 6 until the correct sensitivity adjustment is found REVERSE SENSITIVITY SHUTDOWN Upon a first obstru...

Страница 19: ...a Master Primary ON Operator is set as a Slave Secondary 4 Close Timer OFF Time Delay Close feature is inactive Command to open command to close ON Time Delay Close feature is active Gate opens times...

Страница 20: ...TIONS ACCESSORY WIRE OVERVIEW CLOSE Photo Cell OPEN Photo Cell O P E N E D G E C L O S E E D G E Radio Receiver OPEN CLOSE STOP FIRE LOCK Card Access 1 2 3 4 5 6 7 8 9 0 Key Box 1 2 3 4 5 6 7 8 9 0 Ph...

Страница 21: ...p and reverse the gate to the full closed position and enter a soft shutdown 3 NOTE If the gate was initially activated by a time clock with a contact closure across the Access Input this input will b...

Страница 22: ...l moving 2 One or more non contact sensors shall be located where a risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier Use caution when installing non...

Страница 23: ...tion to reset the operator settings Standard Reverse Input 1 Input is inactive when gate is closed or in the open cycle 2 When gate is open and Time Delay Close is ON an input will reset the Time Dela...

Страница 24: ...ill remain open until an external input is made This prevents the Fire Input from closing the gate if in the open position Connecting Access Devices 1 Connect Fire Lock Control relays to FIRE and COMM...

Страница 25: ...2 If the Radio Receiver uses 24VDC connect Radio Power to RADIO PWR 24VDC and RADIO PWR 24VDC Connecting FAAC XR2 Radio Receivers 1 Connect XR2 N O relay contacts to RADIO N O and RADIO COMMON 2 Conne...

Страница 26: ...ty increase the size of each Solar Panel Connecting Solar Panels 1 Use one 20 Watt 24VDC Solar Panel OR two 20 Watt 12VDC Solar Panels together in series 2 Connect the Solar Panel positive to SOLAR 3...

Страница 27: ...e the loop size 2 Cut loop slots in the driveway Loop slot should be 1 1 2 to 2 deep Loop slot should be 1 4 wide Cut diagonal corner slots to protect the wire insulation and keep the wire from changi...

Страница 28: ...left socket Make sure detector is secure and snapped in 4 Set different frequencies for each loop detector 5 Follow the directions provided with the PLD1500 for more detailed settings Ground Loop Wir...

Страница 29: ...connector While the operator is stopped wiggle the Limit Sensor connector If the limit or sensor wires blink on and off there is a loose connection 2 Start the operator watch Sensor 1 and Sensor 2 at...

Страница 30: ...PCB with heat sink 2 GC3100 Controller PCB heat sink and faceplate assembly 3 GC3000 Controller Assembly No PCB faceplate 4 MOTOR 0500 24 Motor 500W 24VDC 5 SL 0020 Gearbox 15 1 6 SL1000 Limit stand...

Страница 31: ...tor 31 S SPARE PARE P PARTS ARTS Num FAAC p n Description 10 SL 0008 Limit nut guide 11 SWITCH 0100 Limit switch 12 AAA0450 Sensor cup assembly 13 WIRE1101SK Sensors wire assembly with screws 14 AAA 0...

Страница 32: ...product s or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s instructions or has been operated under conditions more severe than...

Отзывы: