Estate Slide E-SL 1200
Accessory Terminals
READ prior to attempting to operate the arm
.
Normally Closed connections must be made for proper gate
opener function
. The full accessory board is only found on the master control board. The slave control board
only contain one Normally Open
J1—Terminal Board for Master Card
Terminals
1
-
“Open/Close Function” This is a normally open terminal where by any device (i.e. push button, keypad, receiver)
which, by closing a contact, provides an opening and/or closing pulse for
both
gate leaves (if there is only one leaf, it
will control the one leaf).
2
-
“Single Leaf Open/Close Function” This is a normally open terminal where by any device (i.e. push button, key-
pad, receiver) which, by closing a contact, provides an opening and/or closing pulse for
only the gate leaf controlled
by the master control board
(if there is only one leaf, it will control the one leaf).
3
-
“Stop Command” This is a normally closed terminal where by any device (i.e. push button) which, by opening a
contact, halts gate movement. I
MPORTANT
: If a connection is not made from this terminal to one of the
-
(negative)
terminals (i.e. 12, 13, 14, 15) gate motion will not commence.
14.1