6. START-UP
6.2 PROGRAMMING THE BOARD
When the display shows the automation status, you
can enter basic or advanced programming mode.
■
Basic programming
1. Press and hold down the
FF
button.
-
The first function (
][
) appears on the display, which
is displayed as long as button F remains pressed.
2. Release the button: the display shows the value
of the function.
3. Press the
++
or
--
button to modify, then press the
FF
button to confirm to go to the next function.
Proceed in the same way for all the functions
(see
Basic programming menu).
■
Advanced programming
1. Press and hold down the
FF
button, then the
++
button
as well:
-
The first function (
bo
) appears on the display,
which is displayed as long as button F remains
pressed.
2. Release the buttons: the display shows the value
of the function.
3. Press the
++
or
--
button to modify, then press the
FF
button to confirm to go to the next function.
Proceed in the same way for all the functions
(see
Advanced programming menu).
■
exiting programming mode
L
Every modified value becomes effective immediately,
but when exiting from programming mode you have to
decide whether to save the modifications or not.
Modifications are lost
due to TIMEOUT if no buttons have
been pressed for 10 minutes or if power to the board is
disconnected before they have been saved.
1. Press and hold down the
FF
button, then the
+
+
button as well.
-
Alternatively, scroll through the programming
menu until you reach the last function (
St
).
2. Select:
Y
= save the changes
no
= DO NOT save the changes
3. Press the button
FF
to confirm.
-
the display reverts to the automation status view.
RISKS
PERSONAL PROTECTIVE EQUIPMENT
SET-UP PROCEDURE
Carry out following (§ specific sections).
1. Check the
STOP
(IN3) and photocell terminals (IN4,
IN5): they have to be connected or bridged.
If terminal IN3 is open, it prevents the automation and the
SETUP
from working.
If terminals IN4 and/or IN5 are open, they prevent the automa-
tion but not the
SETUP
from working.
2. Connect the emergency batteries, if present and
then turn power on to the board.
3. Configure the type of automation (Basic pro-
gramming,
cF
) and the number of motors (Basic
programming,
Mn
).
4. Enable the encoders, if present (Basic program-
ming,
En
) and the limit switches (Basic program-
ming,
FA
,
FC
).
5. If an electric lock has been installed on leaf2, enable
EL=Y
in advanced programming.
6. Check the leaf movement (Basic programming,
M2
,
M1
).
7. Carry out the
SETUP
procedure that includes the
registration of BUS 2easy that are connected (Basic
programming,
tL
).
8. Memorise the radio controls, if used.
9. Complete the required programming.
10. Carry out the final checks to make sure that the
automation system is working correctly with all
the devices installed.
11. Close the board enclosure.
6.1 TURN POWER ON TO THE BOARD
Switch on the mains power supply after having con-
nected the emergency batteries, if present.
The
MAIN
LED lights up and the following appears
on the display:
-
bo
, then the FW version (e.g.
4.0
), then
S0
(
SETUP
required). If the
SETUP
has already been
carried out
bo
, appears on the display and then the
automation status (e.g.
00
).
For LED and display signals see § Diagnostics.