E045
21
732786 - Rev.C
ENGLISH
5.2 ADVANCED PROGRAMMING FUNCTIONS
Display
Advanced Function
Default
rS
REVERSE STROKE IN OPENING
and RAM STROKE IN CLOSING
:
You can enable/disable reverse stroke and ram stroke.
The reverse stroke facilitates releasing the electric lock: when the automa-
ted system is closed, before to start opening, the motors give a short drive
toward closing.
The Ram Stroke facilitate the latching of the electric lock: activating the the
motors at maximum power during the end of closing
.
Y
= enabled (for 2 sec)
no
= disabled
In case of systems with an absolute encoder, to enable this function
a setup must be performed using the automatic leaf stop on the
mechanical contact point.
no
Od
DELAY FOR OPENING LEAF (visualised only with the function
Mn
=
2
):
You can enable/disable the delay for starting leaf 2 opening with respect to leaf
1, in order to avoid overlapping of the two leaves
.
Y
=
enabled (for 2 sec)
no
= disabled
Y
r1
LEAF 1 DECELERATION:
You can adjust the deceleration space as a percentage of the total travel of
leaf 1.
Adjustable from
00
to
99
%, in 1% steps.
00
= no deceleration
01
= minimum deceleration space
99
= maximum deceleration space
20
r2
LEAF 2 DECELERATION (visualised only with the function
Mn
=
2
):
You can adjust the deceleration space as a percentage of the total travel of
leaf 2.
Adjustable from
00
to
99
%, in 1% steps.
00
= no deceleration
01
= minimum deceleration space
99
= maximum deceleration space
20
Содержание E045
Страница 1: ...E045 E045...
Страница 43: ......