8.2
ALARMS
When there is an ALARM the ERROR LED will begin to flash. By simultaneously pr
and - the display will show the corresponding alarm number.
The following table contains all the alarms that can be viewed on the display.
N°
ALARM
Solution/Description
2 0
Obstacle on MOTOR 1 (only with
encoder)
Remove any possible obstacle on leaf 1
2 1
Obstacle on MOTOR 2 (only with
encoder)
Remove any possible obstacle on leaf 2
2 5
LOCK 1 output short-circuit
Remove the cause of the short-circuit
2 8
Nr. of consecutive obstacles
exceeded during closing
Remove any possible obstacle.
Should the problem persist, repeat SETUP
3 0
XF
radio code memory full
Cancel the radio codes.
3 1
Breach alarm
A movement was made with the automated system in
status
St
=
00
or
01
.
Perform an operation cycle.
9. TROUBLESHOOTING
Description
Solution
A
The board does not turn on
•
Ensure that the board is receiving the 230V~
•
Ensure that fuse F1 is intact
B
The gate will not open after
an OPEN pulse
•
Check that the safety devices and STOP are connected
to the negative and ensure that the corresponding LEDs
are ON
•
Check the photocells (alignment, engagement)
•
Check that the SETUP has been completed correctly.
Repeat if necessary
C
The gate does not reverse
when the photocells are
engaged
•
Check that the traditional photocells are correctly wired and
that the BUS photocell configuration is correct (if present).
If necessary, repeat the acquisition of the
BUS-2EASY
devices
D
The gate does not reverse
w h e n e n c o u n t e r i n g a n
obstacle
•
Ensure that the encoders on motors are enabled
•
Check the obstacle detection sensitivity
E
The gate will not close
•
Check that the photocell wiring and alignment is correct
•
Check that there is no OPEN signal active
•
Check which function logic has been chosen (automatic
or semi-automatic)