INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105
15
Revision 3
• Locked settings
Settings in the different channels can be locked by service personnel so that they cannot be changed. Contact an authorised
service engineer, who will have the instructions needed to release the unit for configuration.
• Configuration channels C700 - C712
It is indicated in channel C700 in which application the control will work. There are three main alternatives, gate, door and
road barrier. The subsidiary options are swing, folding or sliding gate or door
It is indicated in channels C701 to C712 which add-in cards are installed. The settings here control to some extent which
channels will be displayed.. If, for example, C707, DB407 output card, is set to 0, none of the o-channels will be shown. The
settings in C700 do not affect the channel display.
• Message channel C904
To facilitate troubleshooting, it is possible choose via channel C904 to display and save in the error code list various events
beyond the error messages. If, for example, safety edge SE.C1 is activated so that reversing takes place, a message, n042, will
be displayed and saved. The message disappears automatically from the display after about a second, but is saved in the error
code list in C903.
• Display channel C999
By entering different values in the display channel, EP105 will switch between different sets of channels. After power on, C700
is displayed as the first channel when C999 is set to 0 or 1. When C999 is set to 2, 3 or 4, C999 is displayed as the first channel.
With C999=0, all channels will be displayed.
With C999=1, channels that are changed in comparison with the factory setting are displayed.
With C999=2, channels for power supply, motor protection and limit switches are displayed. This display mode is used to set
open and closed position.
With C999=3, channels are displayed for pulse/hold-to-run, safe edge, load guard, motor protection, ratio for frequency
inverter, limit switches and application with add-in card. This display mode is used to set the load guard.
With C999=4, Displays channels for selection of application and add-on card. These channels are used to hide or show
additional card channels.
• Käyttöönotto C999-näyttökanavalla
When a new EP105 is switched on for the first time, the C999 is set to 2. Now you can only step around among these
channels using the plus and minus buttons:
C999
, which is the first channel shown
L001
, where the limit position for motor 1 is selected
L002
, where the limit position for motor 2 is selected
C202
, here you select the type of supply voltage
When the C999 is set to 2, you can easily select the supply voltage, set the motor protection and adjust the open and closed
position. When you have selected the limit mode, channels for the selected limit mode type and for the motor protection are
displayed.
When this is done, change the C999 to 3 and proceed with setting the impulse / holder, clamp protection, photocell and load
monitor.
Finish by setting C999 to 4 and select in the channels C700 to C712 application and the additional cards you have connected
to the controller.
Finally, you set the C999 to 0 and you now have access to all channels and can continue with the commissioning of any
additional cards and fine-tune the function of the automatic control. In channel display mode, you can step fast using the left
button.
See the sections "Quick guide for commissioning the swing gate" and "Commissioning" for more information.
Содержание DAAB EP105
Страница 1: ...INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105...
Страница 58: ...INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105 58 Revision 3 Notes...
Страница 59: ...INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP105 59 Revision 3 Notes...
Страница 60: ...Revision 3 FAAC Nordic AB Box 125 SE 284 22 Perstorp 46 435 77 95 00 www faac se support faac se...