Description of function, d-channels

Two vehicle loops can be connected to the automatic control units via DB402 add-in cards – to activate the inputs set channels 

d100 and/or d200 to the value 1. When the unit is delivered and following a reset, channels d100 and d200 are set to 0, 

disabled. The settings below apply to vehicle loop 1, using channel numbers d101 – d190. The functions are the same for 

vehicle loop 2, except that the channels are numbered d201 – d290. See the channel reference.

Configuring the vehicle loop

Activate the vehicle loop inputs by setting channel d100 to 1.

Channels d101, d102 and d103 are used for loop readouts, and channels d110 to d195 are all used to change settings.

The value in channel d102 must be between 08 and 50, otherwise the vehicle loop will not work correctly.

Basic settings for the vehicle loop:

• 

Detection limit

Set the value in channel d110 to detect vehicles on the vehicle loop.

Set the difference between on and off in channel d111

• 

Vehicle loop reset

There are two channels you can use to reset presence on the vehicle loop – d121 for times between 00 – 99 seconds and 

d120 for longer times between 005 – 240 minutes.

The timer starts when the vehicle loop is activated, and the loop is reset even if there is still a signal at the loop when the 

timer ends.

• 

Compensation for door halves

These channel are used if the door halves activate the loops as they open or close. Open and close the door – the readout in 

channel d103 indicates the time of loop activation. Enter the time and increase it until the door no longer activates the loop, 

using channel d131 for the door half operated by motor 1 and d132 for the door half operated by motor 2.

Vehicle loop functions

A number of functions are available when a vehicle loop is activated, using the following channels:

d151, Loop-based closing

Use can use this channel to activate loop-based closing. The value 1 activates loop-based closing and 0 deactivates loop-

based closing.
d154, Type of loop closing

This channel works with d151 to control the function of loop-based closing. Either the door closes as soon as the vehicle 

loop is no longer activated (option 1), or it is left to open fully before closing (option 2).
P160, Control function

This channel is used to enable the opening function with the vehicle loop. The value 0 disables the opening function, and 

the value 1 activates it.
d161, Type of control signal.

This channel works with d160 and determines the type of the open signal from the vehicle loop – either a pulse (option 0) 

or a constant signal while the vehicle loop is activated (option 1).
d162, Half operation

This channel defines which motor will be opened by the vehicle loop. The value 1 opens motor 1, 2 opens motor 2, and 3 

opens both motors 1 and 2.
d163, Limited opening

EP104

If you want limited opening, set this channel to the value 1, the door will then open according to the set time in C412 and 

C414 when a limit switch is used or a specified number of degrees in L116 and L126 when an encoder is used.

EP105

:

If you want limited opening, set this channel to the value 1, the door will then open according to the set time in C216 and 

L226 when a limit switch is used or a specified number of degrees in L116 and L126 when an encoder is used.
d170, Enable operation from a programmable input

This channel allows you to disable the opening function from a programmable input. Make sure that the programmable 

input is active and that all the settings have been disabled. The opening function of the vehicle loop will work for as long as 

there is a signal present at the programmable input specified in this channel.
d175, Delayed opening

This channel delays the open signal, for example to ensure that the door is not opened by passing cars that are not heading 

for the door. The channel is set to the number of seconds you want to delay the open signal.
d190, Interlock, Used to send interlock opening to remote door.

Содержание DAAB DB402

Страница 1: ...or DAAB automatic control unit EP104 EP105 INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402 FAAC Nordic AB BOX 125 SE 284 22 PERSTORP SWEDEN 46 435 77 95 00 support faac se www faac se R e v i s i o n 7...

Страница 2: ...omatic control units Two vehicle loops can be connected to this card Function with activated loop is controlled by the d channels in the automatic control unit The vehicle sensor operates at two diffe...

Страница 3: ...re handling PCB 2 Disconnect the power to the automatic control unit 3 Screw the DB402 card into place on the spacers on the automatic control unit using two M4x6 screws 4 Connect cable to LOOP connec...

Страница 4: ...that the insulation is not damaged If necessary fix the loop in place before backfilling the channel Before backfilling the channel test the loop with the vehicle concerned Loop placement To ensure go...

Страница 5: ...d p a i r o r s h i e l d e d c a b l e SAW CUT SLOT Concrete Asphalt Instruction for laying vehicle loops for gates doors and barriers All dimensions in the table below are in mm For other informati...

Страница 6: ...connected in series using input NC which is a potential free contact It is important to remember that the loops must be of equal circumference to achieve reliable function Indications There are two ye...

Страница 7: ...Use can use this channel to activate loop based closing The value 1 activates loop based closing and 0 deactivates loop based closing d154 Type of loop closing This channel works with d151 to control...

Страница 8: ...c closing or set the value to 3 to send a stop signal without automatic closing The automatic closing timer starts when the vehicle exits the loop d141 Safety during run on time This channel activates...

Страница 9: ...2 on the loop in the closed position 00 50 03 d140 Safety function in closing movement 0 4 1 0 Disabled 1 Reverse 2 Stop with automatic restart of automatic closing 3 Stop without automatic restart o...

Страница 10: ...input 0 6 0 0 Disabled normal opening closing function Programmable input has no function for LOOP1 1 Opening possible only if there is a signal at programmable input 1 2 Opening possible only if the...

Страница 11: ...loop in the closed position 00 50 03 d240 Safety function in closing movement 0 4 1 0 Disabled 1 Reverse 2 Stop with automatic restart of automatic closing 3 Stop without automatic restart of automati...

Страница 12: ...ut 0 6 0 0 Disabled normal opening closing function Programmable input has no function for LOOP2 1 Opening possible only if there is a signal at programmable input 1 2 Opening possible only if there i...

Страница 13: ...INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402 Revision 7 13 Notes...

Страница 14: ......

Отзывы: