C720-C721
5
732568 - Rev.E
Fig. 4
Fig. 6
Fig. 7
300
Fig. 5
ENGLISH
T
ranslation of the original instructions
5.2 MASONRY FOR FOUNDATION PLATE
1. Assemble the foundation plate as shown in Fig. 4.
2. The foundation plate must be located as shown in Fig. 5
(right closing) or Fig. 6 (left closing) to ensure the rack and
pinion mesh correctly.
Dimensions in mm
Positioning of plate with
GALVANISED STEEL rack
NYLON rack
right closure
Positioning of plate with
GALVANISED STEEL rack
NYLON rack
left closure
Dimensions in mm
This symbol
must
always face to-
wards the gate
3. Prepare a foundation plinth as shown in Fig. 7 and wall in the
foundation plate, supplying one or more sheaths for routing
electric cables through the hole in the foundation plate.
Using a spirit level, check if the plate is perfectly
level.
Wait for the cement to set.
4. Lay the electric cables for connection to the accessories
and power supply as shown in Fig. 3.
To facilitate the connections in the control unit,
pull out the leads by at least 30 cm from the
hole on the plate.
Dimensions
in mm
Dimensions
in mm