manualshive.com logo in svg
background image

8

ENGLISH

FAAC 959 B-E

Table 1: Technical specifications of 959 B-E Operator

Power supply

230 Vac (+6 -10%) - 50 (60) Hz

Absorbed power

100 W

Current drawn

0.5 A

Electric motor

24 Vdc with encoder

Dimensions

 

530 x 100 x 104 (length x height x depth)

Weight

10 kg

Ambient temperature

-15 + 70 °C

Housing protection

IP 23

Dimensions and max. weight of leaf

see Table 3 (section 1.1)

Duty cycle

continuous

Operation in event of power failure

Manual push/pull opening

Configuration of driving arms

• pushing articulated arm

(version for jamb depth 0 

÷

 125 mm)

• pushing articulated arm

(version for jamb depth 126 

÷

 250 mm)

• sliding arm

Anti-crushing device

standard

Opening angle

70 

÷

 95°

Opening time

3.5 

÷

 10 s (adjustable)

Closing time

÷

 13 s (adjustable)

Max. weight of leaf

(kg)

Sliding arm

a

Cable hole

b

Support profile

c

959 MP electronic control unit

d

Position monitoring microswitch

e

Transmission shaft

f

Transmission shaft

f

Drive system

g

DC motor

h

959 B-E programming unit

i

Protective casing

j

Operating function switch

k

End cover (2)

Fig. 1

3

1

2

5

6

11

10

9

8

7

4

Max. weight of leaf

(kg)

Pushing articulated arm

Length of leaf

 (mm)

mm

Sliding arm

Table 2: Technical specifications of 959MP Electronic Control

Unit + 959 B-E Programming unit

Power supply

230 Vac (+6 -10%) - 50 (60) Hz

Accessories power supply

24 Vdc / 500 mA max.

Electric lock power supply (N.O./N.C.)

24 Vdc / 0.5 A max.

Standard operating functions (switch)

Open / Automatic / Manual

(Night)

Adjustable functions (trimmer)

 Opening speed - Closing speed

Pulling force - Pause time

Selectable functions (microswitches)

Overclosing stroke

Standard/non-standard initialisation procedure

Push and Go - Function switch (pos. “0”)

Terminal strip outputs

Malfunction alarm signal-

24 Vdc electric lock power supply

 (N.O./N.C.) - 24 Vdc accessories power supply

Terminal strip inputs

Function switch/CODIS (optional) -

Internal / external / emergency /

STOP safety device / CLOSURE safety device

1.1 APPLICATION LIMITS

Important

: To ensure correct application of the FAAC 959 B-E

unit the weight of the door must not exceed the value given in
Table 3 corresponding to its length.
The maximum length of the leaf is 1000 mm.
The values of maximum weight vary according to the driving
arm used.
For each driving arm there is also a different maximum value for
the depth of the doorpost (Table 4) beyond which it is not
possible to install the system correctly.

Table 3: Application limits of 959 B-E automatic unit

700

130

-

750

124

-

800

118

92

850

113

89

900

108

85

950

104

83

1000

100

80

Table 4: Max. depth of doorpost

2. ELECTRICAL SETUP (fig. 2a Standard system)

a

959 B-E operator

b

Microwave radar / Passive infrared sensor

c

T20E external key-switch (KEY command)

d

Emergency Closing/Opening pushbutton

e

CODIS programming unit (optional)

f

CODIS inhibition switch (optional)

g

24 Vdc electric lock

h

Junction box

If the operator is installed on the door, make the electrical
connections using a junction box and suitable commercially
available pipes/unions 

(fig. 2b)

.

Pushing

articulated arm

(Var. 02)

Pushing

articulated arm

(Var. 01)

0 - 125

126 - 250

0 - 160

The 959 B-E automatic unit for swing doors is a one-piece unit
consisting of an electromechanical device that allows door
opening to be controlled by means of a driving arm.
The operator can be installed either on the lintel or on the door
structure itself.
The aluminium protective casing houses the electronic control
unit used to program and control the operation of the system.
In the event of a power failure the door can be pushed (or
pulled) open manually.

1. DESCRIPTION AND TECHNICAL CHARACTERISTICS

Содержание 959 B-E

Страница 1: ...tfreundlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A...

Страница 2: ...bsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amen...

Страница 3: ...with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 12 Ensure that there is a differential switch up line of the electrical...

Страница 4: ...3 ITALIANO Fig 2a Fig 3 Fig 2b Fig 4 Fig 8 2x0 5 mm2 2x0 5 mm 2 2x0 5 mm 2 3x1 5 mm 2 230 V 2 x 0 5 mm 2 6 5 4 3 7 1 8 2 2 2x0 5 mm 2 schermato screened blind abgeschimt apantallado...

Страница 5: ...4 ITALIANO Fig 5 90 90 2 1 2 1 3 7 6 5 4 2 1 a b 45 45 1 3 2 1 4 4 1 a b Fig 6...

Страница 6: ...eje est ndar por una de lasopcionales prolongaci n de 20 mm prolongaci n de 50 mm En tal caso sumar a las cotas interesadas la altura correspondiente 20 50 mm Quote in mm Dimensions in mm Cotes en mm...

Страница 7: ...e der beiden optionalen Verl ngerungen ersetzen Wellenverl ngerung 20 mm Wellenverl ngerung 50 mm In diesem Fall ebenfalls die betreffenden H henma evergr ern 20bzw 50mm Cota con prolongaci n del eje...

Страница 8: ...prolongaci n de 20 mm prolongaci n de 50 mm En tal caso sumar a las cotas interesadas la altura correspondiente 20 50 mm 0 160 Quota con prolunga albero standard Nel caso sia necessario aumentare la d...

Страница 9: ...nal 24 Vdc electric lock power supply N O N C 24 Vdc accessories power supply Terminalstripinputs Functionswitch CODIS optional Internal external emergency STOP safety device CLOSURE safety device 1 1...

Страница 10: ...d use the higher extensions available as accessories see Table A B 4 Mount plate 5 of arm 2 on the door or the lintel using the two M6 screws and the washers provided fig 5 The installation distances...

Страница 11: ...s of the settings Turn the trimmers anticlockwise to reduce the values of the settings 5 3 PROGRAMMING THE MICROSWITCHES fig 10 The programming unit has a series of microswitches which allow the funct...

Страница 12: ...12 STOP safety control fig 19 a any device safety sensor photocell etc which by opening a contact has a safety effect on the operating cycle In particular this safety device interrupts the opening cl...

Страница 13: ...LOCK N O EL LOCK COM L screened cable 2 x 0 5 mm2 50 m max 2 NIGHT ONE WAY CODIS L L 1 2 3 2 1 4 3 0 Vdc 1 1 230 V 6 10 50 60 Hz N F N O C INTERNAL SENSOR N F N O C EXTERNAL CONNECTOR BROWN WHITE GREE...

Страница 14: ...mum opening by 60 to 100 The standard setting is 100 LED 2 o PAUSE TIME adjust to 0 30 seconds Theopeningiscontrolledbymeans Fig 21 g Programming unit connector 14 pole 7 FUNCTION SWITCH The 959 B E o...

Страница 15: ...of lit LEDs indicated in Table 7 5 Pressthe and pushbuttonssimultaneouslytoactivate or deactivate the function and check the status of LED 6 according to the indications of Table 7 Note the standard...

Страница 16: ...onsecutive operating cycles The control devices in any case take priority over the operation of the system The programme can be cancelled by performing a RESET function 18 Level II RESET active inacti...

Страница 17: ...or allow children or adults to stand within range of the door especially during operation and do not leave objects near it Do not allow children to play with the door Do not deliberately obstruct move...

Страница 18: ...ner al d a la presente publicaci n todas las modificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car cter constructivo o comercial FAAC...

Отзывы: