950N 8
732708
- Rev. C
EN
G
L
ISH
IT
A
L
IA
N
O
The 950 N automated system for leaf doors is an enbloc
consisting of an electromechanical device that allows door
opening by means of a transmission arm. The door closes
itself using a spring system.
The operator can be installed either on the architrave or
directly on the door structure.
The protective housing contains the electronic control unit
for system programming and operation control. The 950 N
operator is a reversible operator. Therefore, in the event of
power drop, the door can be opened manually.
Automated system
power supply
230 V~* or 115 V~*
(+6% -10%)
(* Depending on the model)
Absorbed power
100 W
Absorbed current
0,5 A
Electric motor
24 V= with encoder
Dimensions
530 x 105 x 160
L x H x D
Weight
10 Kg
Operating ambient
temperature
- 20° C..........+55°C
Protection
class
IP 23 (indoor use)
Maximum leaf
dimensions and
weight
Section 3
Use frequency
continuous
ROT
Continuous use at 55°C
Operation with
no power
manual push or pull opening
depending on the arm
Type of transmis-
sion arms
•
Articulated
•
Sliding L=330 mm
•
Sliding L=430 mm
Anti-crushing
device
With reverse in case of obstacle
(standard supply)
Maximum
opening angle
Section 3.3
950 N
2 DESCRIPTION AND TECHNICAL SPECIFICA-
TIONS
Opening
time
adjustable
from 4 to 10 seconds
Closing
time
adjustable
from 4 to 10 seconds
Accessories power
Electric
lock power supply
24 V
=
1000mA max
Operating modes
(by selector switch)
Open - Automatic -
Manual or Night
Pause time
adjustable
from 0 to 30 seconds
Modes adjustable
With trimmer: see igure 5
With dip switch: see igures 4
and 6
Terminal board
outputs
•
Board fault signal
•
Electric lock activation
•
Accessories power supply
•
Door status signal
•
Exchange relay controlled
from card reader
•
2-leaf connection signal
•
Signal for interlock between
two doors
Terminal board
inputs
•
Open commands
•
Emergency command
•
Key command
•
Card reader command
•
Fire-prevention command
•
STOP safety
•
Safety during closing
Rapid connectors
•
KP controller/SDK light
(optional)
•
Radio rp, minidec, decoder
board connector
•
Mode selector switch
connector
Mode selection
•
Mode selector switch
•
KP controller
•
SDK light
1
PRELIMINARY CHECKS
For correct operation of the automated system, the existing door structure must feature the following:
1. Length and weight corresponding to the description contained in section 3.1
2. Max. post depth corresponding to the description contained in section 3.2
3. Sturdy and rigid leaf structure.
4. Existing hinges in good condition.
5. Smooth and even movement of the leaf, without irregular friction during the entire stroke.
6. Door “neutral” position during the entire stroke. Should the door tend to close or open, check the alignment of the hinges.
7. Presence of mechanical limit switches.